<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Food Safety Products &#8211; Phoenix Scientific Co., Ltd.</title>
	<atom:link href="https://phoenix-sci.com/product-category/all-categories/food-safety-test/feed/" rel="self" type="application/rss+xml" />
	<link>https://phoenix-sci.com</link>
	<description>A Thailand’s leading provider in scientific and lab solutions.</description>
	<lastBuildDate>Mon, 24 Aug 2026 06:29:08 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://phoenix-sci.com/wp-content/uploads/2024/09/cropped-2025_LOGO-Phoenix-01-Photoroom-32x32.png</url>
	<title>Food Safety Products &#8211; Phoenix Scientific Co., Ltd.</title>
	<link>https://phoenix-sci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>ATP WaterTotal Swab</title>
		<link>https://phoenix-sci.com/product/all-categories/atp-watertotal-swab/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 17 Aug 2026 10:23:22 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28020</guid>

					<description><![CDATA[CleanTrust™ TOTAL measures both ATP contained within living cells and particulate matter (microbial ATP) as well as ATP dissolved in water (non-microbial or dead microbial ATP). Used together, CleanTrust™ TOTAL and CleanTrust™ FREE can be an effective quality monitoring system. The difference between Total and Free swab results represents ATP from living organisms.]]></description>
										<content:encoded><![CDATA[<h4><strong>Order Information:</strong></h4>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="161" />
<col width="326" />
<col width="300" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Product No.</strong></td>
<td style="text-align: center;"><strong>Product Name</strong></td>
<td style="text-align: center;"><strong>Quantity</strong></td>
</tr>
<tr>
<td style="text-align: center;">YL0003</td>
<td style="text-align: center;">CleanTrustTM ATP WaterTotal Swab</td>
<td style="text-align: center;">100 pcs / box</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>Storage &amp; Shelf Life:</strong></h4>
<p>2-8°C , store away from light, valid for 12 months</p>
<p>&nbsp;</p>
<h4><strong>Detection Sensitivity: </strong></h4>
<p>YZ3500: 2.5*10<sup>-16 </sup>mol</p>
<p>&nbsp;</p>
<h4><strong>Product Description:</strong></h4>
<ul>
<li>Suitable friction, easy for sampling</li>
<li>Results in 10 seconds</li>
<li>Low lot-to-lot variation</li>
<li>Self-contained, liquid-stable reagent.</li>
<li>High accuracy and reproducibility</li>
<li>Tolerant to temperature abuse and sanitizer effects</li>
<li>Free and Total formats used to reliably and easily indicate microbial contamination in sample</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ATP WaterFree Swab</title>
		<link>https://phoenix-sci.com/product/all-categories/atp-waterfree-swab/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 17 Aug 2026 10:21:46 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28017</guid>

					<description><![CDATA[CleanTrust™ FREE measures only dissolved ATP outside of living cells (non-microbial ATP). Used together, CleanTrust™ TOTAL and CleanTrust™ FREE can be an effective quality monitoring system. The difference between Total and Free swab results represents ATP from living organisms.]]></description>
										<content:encoded><![CDATA[<h4><strong>Order Information:</strong></h4>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="161" />
<col width="326" />
<col width="300" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Product No.</strong></td>
<td style="text-align: center;"><strong>Product Name</strong></td>
<td style="text-align: center;"><strong>Quantity</strong></td>
</tr>
<tr>
<td style="text-align: center;">YL0004</td>
<td style="text-align: center;">CleanTrust™ ATP Surface Swab</td>
<td style="text-align: center;">100 pcs / box</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>Storage &amp; Shelf Life:</strong></h4>
<p>2-8°C , store away from light, valid for 12 months</p>
<p>&nbsp;</p>
<h4><strong>Detection Sensitivity: </strong></h4>
<p>YZ3500: 2.5*10<sup>-16 </sup>mol</p>
<p>&nbsp;</p>
<h4><strong>Product Description:</strong></h4>
<ul>
<li>Suitable friction, easy for sampling</li>
<li>Results in 10 seconds</li>
<li>Low lot-to-lot variation</li>
<li>Self-contained, liquid-stable reagent.</li>
<li>High accuracy and reproducibility</li>
<li>Tolerant to temperature abuse and sanitizer effects</li>
<li>Free and Total formats used to reliably and easily indicate microbial contamination in sample</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Surface Protein Allergen Test Swab</title>
		<link>https://phoenix-sci.com/product/all-categories/surface-protein-allergen-test-swab/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 17 Aug 2026 10:17:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28014</guid>

					<description><![CDATA[The CleanTrust™<sup> </sup>Surface Protein Allergen Test Swab is a ready to use rapid test swab with high sensitivity, used to detect protein residues on surface, and thereby determine if cleaning has been effective in eliminating proteins, including potentially allergenic proteins. After smearing the surface of the object, if protein is present, the solution will change from green to purple. The faster and darker the color change, the higher the protein content. lt is important to note that a residue may contain a mixture of allergenic and non-allergenic proteins, as well as non-protein materials.]]></description>
										<content:encoded><![CDATA[<h4><strong>Order Information:</strong></h4>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="161" />
<col width="326" />
<col width="300" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Product No.</strong></td>
<td style="text-align: center;"><strong>Product Name</strong></td>
<td style="text-align: center;"><strong>Quantity</strong></td>
</tr>
<tr>
<td style="text-align: center;">YL0200</td>
<td style="text-align: center;">CleanTrustTM Surface Protein Allergen Test Swab</td>
<td style="text-align: center;">100 pcs / box</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>Storage &amp; Shelf Life:</strong></h4>
<p>2-8°C , store away from light, valid for 12 months</p>
<p>&nbsp;</p>
<h4><strong>Detection Sensitivity: </strong></h4>
<p>5 µg after 15 minutes incubation at 37°C</p>
<p>&nbsp;</p>
<h4><strong>Product Description:</strong></h4>
<ul>
<li>Easy to use, no extra reagent needed</li>
<li>High sensitivity, detects as little as 5 ug of protein</li>
<li>Suitable for protein-based allergens monitoring</li>
<li>Visual interpretation, no instrument needed<br />
<img fetchpriority="high" decoding="async" class="alignnone  wp-image-28039" src="https://phoenix-sci.com/wp-content/uploads/2026/08/image-7.webp" alt="" width="629" height="197" srcset="https://phoenix-sci.com/wp-content/uploads/2026/08/image-7.webp 1369w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-7-300x94.webp 300w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-7-1024x321.webp 1024w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-7-768x241.webp 768w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-7-600x188.webp 600w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-7-64x20.webp 64w" sizes="(max-width: 629px) 100vw, 629px" /></li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Surface Protein Test Swab</title>
		<link>https://phoenix-sci.com/product/all-categories/surface-protein-test-swab/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 17 Aug 2026 10:15:39 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28011</guid>

					<description><![CDATA[The CleanTrust™ Surface Protein Test Swab is a ready to use rapid test swab used to detect protein residues on cleaned surfaces. After smearing the surface of the object, if protein is present, the solution will change from green to purple. The faster and darker the color change, the higher the protein content.]]></description>
										<content:encoded><![CDATA[<h4><strong>Order Information:</strong></h4>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="161" />
<col width="326" />
<col width="300" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Product No.</strong></td>
<td style="text-align: center;"><strong>Product Name</strong></td>
<td style="text-align: center;"><strong>Quantity</strong></td>
</tr>
<tr>
<td style="text-align: center;">YL0100</td>
<td style="text-align: center;">CleanTrust™ Surface Protein Test Swab</td>
<td style="text-align: center;">100 pcs / box</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>Storage &amp; Shelf Life:</strong></h4>
<p>2-8°C , store away from light, valid for 12 months</p>
<p>&nbsp;</p>
<h4><strong>Detection Sensitivity: </strong></h4>
<p>Room temperature(20-25°C):</p>
<p>80µg after 1 minute</p>
<p>50µg after 5 minutes</p>
<p>20µg after 10 minutes</p>
<p>&nbsp;</p>
<h4><strong>Product Description:</strong></h4>
<ul>
<li>Easy to use, no extra reagent needed</li>
<li>Quick and stable, result in 1-10 minutes</li>
<li>Visual interpretation, no instrument needed<br />
<img decoding="async" class="alignnone  wp-image-28035" src="https://phoenix-sci.com/wp-content/uploads/2026/08/image-6.webp" alt="" width="565" height="168" srcset="https://phoenix-sci.com/wp-content/uploads/2026/08/image-6.webp 1265w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-6-300x89.webp 300w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-6-1024x304.webp 1024w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-6-768x228.webp 768w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-6-600x178.webp 600w, https://phoenix-sci.com/wp-content/uploads/2026/08/image-6-64x19.webp 64w" sizes="(max-width: 565px) 100vw, 565px" /></li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ATP Surface Swab (AOAC Validated)</title>
		<link>https://phoenix-sci.com/product/all-categories/atp-surface-swab-aoac-validated/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 17 Aug 2026 10:02:34 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28003</guid>

					<description><![CDATA[The CleanTrust™ ATP Surface Swab is a user-friendly, all-in-one tool for ATP surface sampling, suitable for rapid on-site testing in food, healthcare products, cosmetics, pharmaceuticals, catering, health supervision, large testing institutions, hospitals, and government regulatory departments.]]></description>
										<content:encoded><![CDATA[<h4><strong>Order Information:</strong></h4>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="161" />
<col width="326" />
<col width="300" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Product No.</strong></td>
<td style="text-align: center;"><strong>Product Name</strong></td>
<td style="text-align: center;"><strong>Quantity</strong></td>
</tr>
<tr>
<td style="text-align: center;">YL0002</td>
<td style="text-align: center;">CleanTrust™ ATP Surface Swab</td>
<td style="text-align: center;">100 pcs / box</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>Sensitivity:</strong></h4>
<p>5*10<sup>-16</sup> mol （YL0002）, compatible with <a href="https://phoenix-sci.com/product/all-categories/yz3500s-luminometer/">YZ3500S Luminometer</a></p>
<p>&nbsp;</p>
<h4><strong>Product Description:</strong></h4>
<ul>
<li>Suitable friction: Easy for sampling</li>
<li>Smart design to ensure sampling of tough surface</li>
<li>Pre-moistened swab bud: Low lot-to-lot variation</li>
<li>Self-contained, liquid-stable reagent</li>
<li>High accuracy and reproducibility</li>
<li>Tolerant to temperature abuse</li>
<li>Four weeks shelf life at room temperature (21-25°C)</li>
<li>Test wet or dry surfaces</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ATP Reader &#8211; YZ3500S Luminometer (AOAC Validated)</title>
		<link>https://phoenix-sci.com/product/all-categories/yz3500s-luminometer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 17 Aug 2026 09:45:19 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=27993</guid>

					<description><![CDATA[YZ3500S Luminometer benchmarks the most advanced and well-known brand of Luminometer, and provides the most reliable and cost-effective ATP solution. Combining with the detection reagents, enables a quick detection on surface and water cleanliness and verify the cleanliness effectively. It features a 5.5" touch screen, Android operating system, analysis software in computer end and intelligent cloud platform.]]></description>
										<content:encoded><![CDATA[<h4><strong>Order Information:</strong></h4>
<table dir="ltr" border="1" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="161" />
<col width="326" />
<col width="300" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Product No.</strong></td>
<td style="text-align: center;"><strong>Product Name</strong></td>
<td style="text-align: center;"><strong>Sensitivity</strong></td>
</tr>
<tr>
<td style="text-align: center;">YZ3500S</td>
<td style="text-align: center;">YZ3500S Luminometer</td>
<td style="text-align: center;">5*10<sup>-16</sup> mol</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<h4><strong>Application scenario:</strong></h4>
<p>Widely used in food, health care products, cosmetics, pharmaceutical, catering enterprises, health supervision, hospital large testing institutions, as well as government supervision functions of the field rapid testing.</p>
<p>&nbsp;</p>
<h4><strong>Product Description:</strong></h4>
<ul>
<li><strong>Ultra-Sensitive Detection</strong><br />
Advanced photodiode module with precise algorithms ensures the most reliable ATP testing.</li>
<li><strong>Calibration-Free Operation</strong><br />
No annual calibration needed, minimizing maintenance and maximizing uptime.</li>
<li><strong>Fast &amp; Accurate Results</strong><br />
Delivers precise readings within 10 seconds after sampling for efficient testing.</li>
<li><strong>Intuitive Touchscreen &amp; APP</strong><br />
5.5-inch capacitive display with one-handed operation and user-friendly interface.</li>
<li><strong>Smart Data &amp; Cloud Management</strong><br />
Automatic data classification, cloud synchronization, and continuous software updates for seamless analysis.</li>
<li><strong>User-Interface Customization</strong></li>
</ul>
<p style="padding-left: 40px;">Supports multiple display languages and customizable interface styles and themes.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MaxSignal® IAC Total Deoxynivalenol</title>
		<link>https://phoenix-sci.com/product/all-categories/food-safety-test/immunoaffinity-column/deoxynivalenol-3-adon-15-adon/maxsignal-iac-total-deoxynivalenol/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 19 Feb 2025 07:12:04 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/maxsignal-iac-total-deoxynivalenol/</guid>

					<description><![CDATA[The MaxSignal<sup>®</sup> Total Deoxynivalenol Immunoaffinity Column (IAC) kit is designed for quantitative analysis of Deoxynivalenol (DON) and its derivatives (3-ADON, 15-ADON) using HPLC or LC-MS/MS.]]></description>
										<content:encoded><![CDATA[<div class="pe_pdpDetails">
<p>This MaxSignal Total Deoxynivalenol Immunoaffinity Column can extract Deoxynivalenol (Vomitoxin, DON), as well as its two prominent acetylated derivatives, 3-acetyldeoxynivalenol (3-ADON) and 15-acetyldeoxynivalenol (15-ADON), which has a highly targeted purification effect. The purified sample solution can be directly used for HPLC or LC-MS/MS analysis after concentrating with nitrogen gas.</p>
<p>DON belongs to the single-endomycin family of molds and is produced by certain <em>Fusarium</em> fungi. 3-ADON and 15-ADON are derivatives of DON. These toxins are mostly distributed in grain seeds such as wheat, barley, and corn. Due to their high cytotoxicities and immunosuppressive properties, they pose a health threat to humans and animals.</p>
<p>The basis of the IAC measurement is the antigen-antibody interaction. All main toxin antibodies are embedded throughout the column. After a sample is extracted and filtered, it is slowly passed through the IAC. The toxins bind to their corresponding antibody in the column. The IAC is then washed to remove unbound substances. The toxins are then eluted with the eluent, concentrated using nitrogen gas, then injected into an analytical instrument for detection. Affinity columns can be used in combination with HPLC and LC-MSMS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.</p>
<p><em>This kit is manufactured to the international quality standard ISO 9001.</em></p>
<p>&nbsp;</p>
</div>
<div class="pe_pdp_detatabl_cont">
<h5 style="text-align: center;">Specifications</h5>
<div class="pe_pdp_detatabl">
<table id="pe_pdp_tab_det" width="449">
<tbody>
<tr>
<th style="text-align: left;" scope="col"><strong>Product Brand Name</strong></th>
<td style="text-align: left;">MaxSignal</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Quantity in a Package Amount</strong></th>
<td>25 pieces</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Type</strong></th>
<td>Grain, Feed</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Volume</strong></th>
<td style="text-align: left;">3 mL</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MaxSignal® IAC Fumonisin</title>
		<link>https://phoenix-sci.com/product/all-categories/food-safety-test/immunoaffinity-column/fumonisin/maxsignal-iac-fumonisin/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 19 Feb 2025 07:12:04 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/maxsignal-iac-fumonisin/</guid>

					<description><![CDATA[This MaxSignal Fumonisin Immunoaffinity Column can selectively extract Fumonisins (B1, B2, B3) from the sample solution.]]></description>
										<content:encoded><![CDATA[<div class="pe_pdpDetails">
<p>This MaxSignal Fumonisin Immunoaffinity Column can selectively extract Fumonisins (B1, B2, B3) from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC or LC-MS/MS analysis after concentrating with nitrogen gas and resuspended.</p>
<p>Fumonisin is a metabolite produced by <em>Fusarium</em> fungi. It has acute and chronic toxicities, and is species-specific and organ-specific. Studies have found that high concentrations of fumonisin can cause acute species-specific toxicity symptoms in many domestic and laboratory animals, such as equine leukoencephalomalacia, porcine pulmonary edema, and liver and kidney diseases in sheep. The toxin has also been found to be related to esophageal and liver cancer in humans.</p>
<p>The basis of the IAC measurement is the antigen-antibody interaction. All the main toxin antibodies are embedded throughout the column. After a sample is extracted and filtered, it is slowly passed through the IAC. The toxins bind to their corresponding antibody in the column. The IAC is then washed to remove unbound substances. The toxins are then eluted with the eluent, concentrated using nitrogen gas, then injected into an analytical instrument for detection. Affinity columns can be used in combination with HPLC and LC-MSMS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.</p>
<p><em>This kit is manufactured to the international quality standard ISO 9001.</em></p>
<p>&nbsp;</p>
</div>
<div class="pe_pdp_detatabl_cont">
<h5 style="text-align: center;">Specifications</h5>
<div class="pe_pdp_detatabl">
<table id="pe_pdp_tab_det">
<tbody>
<tr>
<th style="text-align: left;" scope="col"><strong>Product Brand Name</strong></th>
<td style="text-align: left;">MaxSignal</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Quantity in a Package Amount</strong></th>
<td>25 pieces</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Type</strong></th>
<td>Grain, Feed</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Volume</strong></th>
<td style="text-align: left;">3 mL</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MaxSignal® IAC Ochratoxin A</title>
		<link>https://phoenix-sci.com/product/all-categories/food-safety-test/immunoaffinity-column/ochratoxin-a/maxsignal-iac-ochratoxin-a/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 19 Feb 2025 07:12:04 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/maxsignal-iac-ochratoxin-a/</guid>

					<description><![CDATA[The MaxSignal<sup>®</sup> Ochratoxin A Immunoaffinity Column (IAC) kit is designed for quantitative analysis of Ochratoxin A using HPLC or LC-MS/MS.]]></description>
										<content:encoded><![CDATA[<div class="pe_pdpDetails">
<p>This MaxSignal Fumonisin Immunoaffinity Column can selectively extract Ochratoxin A from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC or LC-MS/MS analysis after being concentrated with nitrogen gas and resuspended.</p>
<p>Ochratoxin A is a toxic metabolite produced by some species of Aspergillus and Penicillium; it is a mycotoxin with high kidney and liver toxicities, and has teratogenic, mutagenic, and carcinogenic effects.</p>
<p>The basis of the IAC measurement is the antigen-antibody interaction. All the main toxin antibodies are embedded throughout the column. After a sample is extracted and filtered, it is slowly passed through the IAC. The toxins bind to their corresponding antibody in the column. The IAC is then washed to remove unbound substances. The toxins are then eluted with the eluent, concentrated using nitrogen gas, then injected into an analytical instrument for detection. Affinity columns can be used in combination with HPLC and LC-MSMS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.</p>
<p><em>This kit is manufactured to the international quality standard ISO 9001.</em></p>
<p>&nbsp;</p>
</div>
<div class="pe_pdp_detatabl_cont">
<h5 style="text-align: center;">Specifications</h5>
<div class="pe_pdp_detatabl">
<table id="pe_pdp_tab_det">
<tbody>
<tr>
<th style="text-align: left;" scope="col"><strong>Product Brand Name</strong></th>
<td style="text-align: left;">MaxSignal</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Quantity in a Package Amount</strong></th>
<td>25 pieces</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Type</strong></th>
<td>Cereal, Nut, Feed, Alcohol, Condiment, Herbs</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Volume</strong></th>
<td style="text-align: left;">3 mL</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MaxSignal® IAC T-2/HT-2 Toxin</title>
		<link>https://phoenix-sci.com/product/all-categories/food-safety-test/immunoaffinity-column/t-2-ht-2/maxsignal-iac-t-2-ht-2-toxin/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 19 Feb 2025 07:12:04 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/maxsignal-iac-t-2-ht-2-toxin/</guid>

					<description><![CDATA[The MaxSignal<sup>®</sup> T-2/HT-2 Immunoaffinity Column (IAC) kit is designed for quantitative analysis of T-2 and HT-2 Toxins using HPLC or LC-MS/MS.]]></description>
										<content:encoded><![CDATA[<div class="pe_pdpDetails">
<p>This MaxSignal T-2/HT-2 Toxin Immunoaffinity Column can selectively extract T-2 and HT-2 Toxins from the sample solution, thereby having a highly targeted purification effect on the sample. The sample solution that has been purified by passing through the column can be directly used for HPLC or LC-MS/MS analysis after being concentrated with nitrogen gas and resuspended.</p>
<p>T-2 toxin (T-2) is a mycotoxin produced by a variety of <em>Fusaria</em>. It mainly pollutes food crops such as wheat, barley, and corn, and their products, and is relatively harmful to human health and cattle industry. HT-2 toxin is the main metabolite of T-2 toxin. These two toxins are strong inhibitors of protein synthesis in the body and mainly affect the functions of blood, liver, kidney, pancreatic muscle and lymphocytes. The general clinical symptoms after poisoning are anorexia, vomiting, diarrhea, growth arrest, as well as reproduction and neurological dysfunction, etc.</p>
<p>The basis of the IAC measurement is the antigen-antibody interaction. All the main toxin antibodies are embedded throughout the column. After a sample is extracted and filtered, it is slowly passed through the IAC. The toxins bind to their corresponding antibody in the column. The IAC is then washed to remove unbound substances. The toxins are then eluted with the eluent, concentrated using nitrogen gas, then injected into an analytical instrument for detection. Affinity columns can be used in combination with HPLC and LC-MSMS to achieve rapid testing, and to increase signal-to-noise ratio and improve the accuracy of the detection method.</p>
<p><em>This kit is manufactured to the international quality standard ISO 9001.</em></p>
<p>&nbsp;</p>
</div>
<div class="pe_pdp_detatabl_cont">
<h5 style="text-align: center;">Specifications</h5>
<div class="pe_pdp_detatabl">
<table id="pe_pdp_tab_det">
<tbody>
<tr>
<th style="text-align: left;" scope="col"><strong>Product Brand Name</th>
<td style="text-align: left;">MaxSignal</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Quantity in a Package Amount</th>
<td>25 pieces</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Type</th>
<td>Grain, Feed, Condiment</td>
</tr>
<tr>
<th style="text-align: left;" scope="col"><strong>Sample Volume</th>
<td style="text-align: left;">3 mL</td>
</tr>
</tbody>
</table>
</div>
</div>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
