<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Automation &#8211; Phoenix Scientific Co., Ltd.</title>
	<atom:link href="https://phoenix-sci.com/product-category/all-categories/automation/feed/" rel="self" type="application/rss+xml" />
	<link>https://phoenix-sci.com</link>
	<description>A Thailand’s leading provider in scientific and lab solutions.</description>
	<lastBuildDate>Mon, 28 Sep 2026 09:45:50 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://phoenix-sci.com/wp-content/uploads/2024/09/cropped-2025_LOGO-Phoenix-01-Photoroom-32x32.png</url>
	<title>Automation &#8211; Phoenix Scientific Co., Ltd.</title>
	<link>https://phoenix-sci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Auto SPE-06D</title>
		<link>https://phoenix-sci.com/product/auto-spe-06d/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Thu, 24 Apr 2025 02:17:26 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24775</guid>

					<description><![CDATA[&#160; Both available in disk or column extraction This SPE equipment can simultaneously process 6 samples Built-in concentration module for nitrogen blowing Compact design for fume hood &#160; Parameter Specification Extraction channel 6 SPE disk size 47mm SPE cartridge size 3mL, 6mL Sample volume 10mL to 20L Solvent capacity 8 Software interface Windows PC; WIFI connection Voltage [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>Both available in disk or column extraction</li>
<li>This SPE equipment can simultaneously process 6 samples</li>
<li>Built-in concentration module for nitrogen blowing</li>
<li>Compact design for fume hood</li>
</ul>
<p>&nbsp;</p>
<div class="overflow-x">
<table width="381" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td class="et3" width="175" height="15"><strong>Parameter</strong></td>
<td class="et4" width="206"><strong>Specification</strong></td>
</tr>
<tr>
<td class="et5" width="175" height="15">Extraction channel</td>
<td class="et5" width="206">6</td>
</tr>
<tr>
<td class="et5" width="175" height="15">SPE disk size</td>
<td class="et5" width="206">47mm</td>
</tr>
<tr>
<td class="et5" width="175" height="15">SPE cartridge size</td>
<td class="et5" width="206">3mL, 6mL</td>
</tr>
<tr>
<td class="et6" width="175" height="15">Sample volume</td>
<td class="et6" width="206">10mL to 20L</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Solvent capacity</td>
<td class="et5" width="206">8</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Software interface</td>
<td class="et5" width="206">Windows PC; WIFI connection</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Voltage</td>
<td class="et5" width="206">200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Operating temperature</td>
<td class="et5" width="206">10 to 40°C</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Operating humidity</td>
<td class="et5" width="206">20 to 80%</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SPEva Automated SPE &#038; Evaporation System</title>
		<link>https://phoenix-sci.com/product/speva-automated-spe-evaporation-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 03:29:20 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24210</guid>

					<description><![CDATA[SPEVA is designed to integrate solid phase extraction and nitrogen evaporation processes. It automatically completes the steps of conditioning, sample loading, rinsing, drying and elution, while continuously evaporating and solvent replacement of the eluent and then passing through the cartridge again.]]></description>
										<content:encoded><![CDATA[<p><iframe title="SPEVA Automated Sample purification and Concentration System" width="800" height="450" src="https://www.youtube.com/embed/CH-pCHJ3SvE?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<ul>
<li>Able to load samples via needles, pipettes, large-volume kit</li>
<li>Simultaneously process 6 samples</li>
<li>SPE and nitrogen blowing in one system</li>
<li>User-friendly software</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td width="178"><strong>Parameter</strong></td>
<td width="351"><strong>Specification</strong></td>
</tr>
<tr>
<td width="178">Extraction channel</td>
<td width="351">6</td>
</tr>
<tr>
<td width="178">SPE cartridge size</td>
<td width="351">3mL, 6mL</td>
</tr>
<tr>
<td width="313">Sample volume</td>
<td width="351">10mL to 20L</td>
</tr>
<tr>
<td width="178">Solvent capacity</td>
<td width="351">8</td>
</tr>
<tr>
<td width="178">Software interface</td>
<td width="351">Windows PC; WIFI connection</td>
</tr>
<tr>
<td width="178">Voltage</td>
<td width="351">200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td width="178">Operating temperature</td>
<td width="351">10 to 40°C</td>
</tr>
<tr>
<td width="178">Operating humidity</td>
<td width="351">20 to 80%</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fotector Series Automated SPE Systems</title>
		<link>https://phoenix-sci.com/product/fotector-series-automated-spe-systems/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 03:22:40 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24201</guid>

					<description><![CDATA[&#160; Fully automated solid-phase extraction, minimal operator intervention Accurate flow rate control to ensure parallelism Multiple extraction channels, consistent batch processing Efficient operation mode through sychronous rack positioning and fast solvent switch Flexible operation with various modules for different applications Graphical software interface, remote real-time monitoring &#160; Parameter Specification Product Fotector 02HT Fotector Plus Fotector [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><iframe title="RayKol Fotector series Automated Solid Phase Extraction System / Automated SPE System" width="800" height="450" src="https://www.youtube.com/embed/Z7aqPlfvUJo?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<ul>
<li>Fully automated solid-phase extraction, minimal operator intervention</li>
<li>Accurate flow rate control to ensure parallelism</li>
<li>Multiple extraction channels, consistent batch processing</li>
<li>Efficient operation mode through sychronous rack positioning and fast solvent switch</li>
<li>Flexible operation with various modules for different applications</li>
<li>Graphical software interface, remote real-time monitoring</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td><strong>Parameter</strong></td>
<td style="text-align: center;" colspan="4"><strong>Specification</strong></td>
</tr>
<tr>
<td>Product</td>
<td>Fotector 02HT</td>
<td>Fotector Plus</td>
<td>Fotector 08HT</td>
<td>FS 360</td>
</tr>
<tr>
<td>Extraction channel</td>
<td>2 channels in parallel</td>
<td>6 channels in parallel</td>
<td>8 channels in parallel</td>
<td>6 channels in parallel</td>
</tr>
<tr>
<td>Sample capacity</td>
<td>20, 12</td>
<td>60, 36</td>
<td>80, 48</td>
<td>36</td>
</tr>
<tr>
<td>SPE cartridge size</td>
<td>3mL, 6mL</td>
<td>1mL, 3mL, 6mL, 12mL, 20mL</td>
<td>1mL, 3mL, 6mL</td>
<td>3mL, 6mL, 12mL</td>
</tr>
<tr>
<td>Sample vials</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 80mL</td>
</tr>
<tr>
<td>Collection vials</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 80mL</td>
</tr>
<tr>
<td>Solvent capacity</td>
<td>8</td>
<td>8</td>
<td>8</td>
<td>8</td>
</tr>
<tr>
<td>Flow rate</td>
<td>0.1 to 100mL/min</td>
<td>0.1 to 100mL/min</td>
<td>0.1 to 100mL/min</td>
<td>0.1 to 100mL/min</td>
</tr>
<tr>
<td>Gas supply and connection</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
</tr>
<tr>
<td>Fume hood/ventilation</td>
<td>Required</td>
<td>Required</td>
<td>Required</td>
<td>Required</td>
</tr>
<tr>
<td>Control software</td>
<td>Windows PC; WIFI connection</td>
<td>Windows PC; WIFI connection</td>
<td>Windows PC; WIFI connection</td>
<td>Windows PC; WIFI connection</td>
</tr>
<tr>
<td>Dimension</td>
<td>40cm x 38cm x 58cm</td>
<td>62cm x 38cm x 63cm</td>
<td>77cm x 45cm x 64cm</td>
<td>62cm x 38cm x 63cm</td>
</tr>
<tr>
<td>Weight</td>
<td>30kg</td>
<td>68kg</td>
<td>72kg</td>
<td>68kg</td>
</tr>
<tr>
<td>Power supply</td>
<td>200 to 240V, 50/60Hz</td>
<td>200 to 240V, 50/60Hz</td>
<td>200 to 240V, 50/60Hz</td>
<td>200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>0 to 40°C</td>
<td>0 to 40°C</td>
<td>0 to 40°C</td>
<td>0 to 40°C</td>
</tr>
<tr>
<td>Storage humidity</td>
<td>20 to 85%</td>
<td>20 to 85%</td>
<td>20 to 85%</td>
<td>20 to 85%</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>10 to 40°C</td>
<td>10 to 40°C</td>
<td>10 to 40°C</td>
<td>10 to 40°C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>20 to 80%</td>
<td>20 to 80%</td>
<td>20 to 80%</td>
<td>20 to 80%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DRQ Automated QuEChERS Extraction</title>
		<link>https://phoenix-sci.com/product/drq-automated-quechers-extraction/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 03:19:57 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24198</guid>

					<description><![CDATA[RayKol DRQ Automated QuEChERS Extraction System is an innovation benchtop automated sample preparation system specialized in QuEChERS method. The compact and hooded design makes it free the fume hood space and easy to position. It does not require any manual involvement after sample weighing, applicable to any automated QuEChERS methods required steps of liquid dispensing, [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><iframe title="HUI BIAO Testing-DRQ Automated QuEChERS Extraction System" width="800" height="450" src="https://www.youtube.com/embed/f63-Lsbl0r0?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>RayKol DRQ Automated QuEChERS Extraction System is an innovation benchtop automated sample preparation system specialized in QuEChERS method. The compact and hooded design makes it free the fume hood space and easy to position. It does not require any manual involvement after sample weighing, applicable to any automated QuEChERS methods required steps of liquid dispensing, shaking, centrifugation, and separation.</p>
<ul class=" list-paddingleft-2">
<li>Batch continuously processing, max. 48 samples</li>
<li>Fullly automated QuEChERS method</li>
<li>Efficient dual-channel capping design</li>
<li>Compact benchtop design</li>
</ul>
<p>&nbsp;</p>
<table width="525" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td class="et4" width="139" height="15"><strong>Parameter</strong></td>
<td class="et5" width="386"><strong>Specification</strong></td>
</tr>
<tr>
<td class="et6" width="139" height="15">Sample capacity</td>
<td class="et7" width="386">Max. 48 samples</td>
</tr>
<tr>
<td class="et8" width="139" height="15">Sample tube</td>
<td class="et9" width="386">50mL/15mL centrifuge vial</td>
</tr>
<tr>
<td class="et10" width="139" height="15">Software interface</td>
<td class="et11" width="386">Built-in screen</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>High-Throughput Pressurized Fluid Extraction System</title>
		<link>https://phoenix-sci.com/product/pressurized-fluid-extraction/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Thu, 17 Apr 2025 04:33:35 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=23959</guid>

					<description><![CDATA[The RayKol HPFE High-Throughput Pressurized Fluid Extraction System automates the extraction process through software-controlled operation, helping to shorten extraction time and reduce solvent consumption compared with conventional Soxhlet extraction.]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p><iframe loading="lazy" title="RayKol HPFE | High-Throughput Pressurized Fluid Extraction for Labs" width="800" height="450" src="https://www.youtube.com/embed/j0lM--RdMws?feature=oembed" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>Pressurized Fluid Extraction (PFE), also known as Accelerated Solvent Extraction (ASE), Pressurized Solvent Extraction (PSE), or Pressurized Liquid Extraction (PLE), is a sample preparation technique used to extract organic compounds from solid and semi-solid samples.</p>
<p>The RayKol HPFE High-Throughput Pressurized Fluid Extraction System automates the extraction process through software-controlled operation, helping to shorten extraction time and reduce solvent consumption compared with conventional Soxhlet extraction.</p>
<p>The HPFE system can be used for the extraction of organic compounds, pesticides, and polychlorinated biphenyls (PCBs) from soil and sediment samples. It can also be combined with a parallel vacuum evaporation system for subsequent concentration of extracts, providing an integrated sample preparation workflow for soil and environmental analysis.</p>
<p>Compared with conventional Soxhlet extraction, RayKol states that the extraction time can be reduced from more than 10 hours to approximately 15–30 minutes, while solvent consumption can be reduced from approximately 200 mL to 20–50 mL.</p>
<p><strong>Key Features</strong></p>
<ul>
<li>Up to 6 extraction channels operating simultaneously</li>
<li>High sample throughput of ≥96 samples per day</li>
<li>Supports 4 selectable solvents</li>
<li>Automatic solvent addition with flexible solvent mixing ratios</li>
<li>Supports 11–120 mL extraction vessels</li>
<li>Supports 60–240 mL collection tubes</li>
<li>Compatible with a concentration module</li>
<li>Suitable for a wide range of solid and semi-solid samples</li>
<li>Built-in 10-inch touchscreen for system control</li>
<li>Programmable extraction methods with one-touch method operation</li>
<li>Multiple safety protections, including overpressure, overtemperature, and leakage protection</li>
<li>Sealed system design with active exhaust</li>
<li>Automatic system monitoring, operation logs, and method error alerts</li>
</ul>
<p>&nbsp;</p>
<p><strong>Applications</strong></p>
<p><strong>Environmental Analysis:</strong> Extraction of organic contaminants, pesticides, PCBs, and herbicides from soil,<br />
sediment, and solid waste.</p>
<p><strong>Food Analysis:</strong> Sample preparation for pesticide residues and food additives.</p>
<p><strong>Agricultural Analysis:</strong> Pesticide residues in agricultural products and oil extraction from seeds.</p>
<p><strong>Other Applications:</strong> Polymers, pharmaceuticals, and petrochemicals.</p>
<p>&nbsp;</p>
<p><strong>Application Examples</strong></p>
<ul>
<li>HJ 77 Series — Determination of Dioxins by Isotope Dilution Gas Chromatography–High Resolution Mass Spectrometry (GC-HRMS)</li>
<li>HJ 782-2016 — Pressurized Fluid Extraction of Organic Compounds from Solid Waste</li>
<li>HJ 783-2016 — Pressurized Fluid Extraction of Organic Compounds from Soil and Sediment</li>
<li>GB/T 23376-2009 — Determination of Multiple Pesticide Residues in Tea by Gas Chromatography/Mass Spectrometry (GC-MS)</li>
<li>GB 23200.9-2016 — Determination of 475 Pesticide and Related Chemical Residues in Grains by Gas Chromatography-Mass Spectrometry</li>
<li>GB/T 22996-2008 — Determination of Various Ginsenosides in Ginseng by Liquid Chromatography with Ultraviolet Detection</li>
<li>ASTM D7567-2009 — Determination of Gel Content in Crosslinked Ethylene Plastics by Pressurized Solvent Extraction</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td><strong>Parameter</strong></td>
<td><strong>Specification</strong></td>
</tr>
<tr>
<td>Extraction channel</td>
<td>6</td>
</tr>
<tr>
<td>Pump pressure range</td>
<td>Atmospheric pressure to 200bar(20MPa)</td>
</tr>
<tr>
<td>Flow rate</td>
<td>0 to 70mL/min</td>
</tr>
<tr>
<td>Temperature range</td>
<td>Room temperature to 200°C (±1°C)</td>
</tr>
<tr>
<td>Solvent capacity</td>
<td>4</td>
</tr>
<tr>
<td>Extraction cell</td>
<td>11mL, 22mL, 34mL</td>
</tr>
<tr>
<td>Collection vials</td>
<td>60 to 370mL</td>
</tr>
<tr>
<td>Software interface</td>
<td>10-inch built-in screen</td>
</tr>
<tr>
<td>Dimension</td>
<td>72cm x 56cm x 77cm</td>
</tr>
<tr>
<td>Weight</td>
<td>120kg</td>
</tr>
<tr>
<td>Power supply</td>
<td>200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td>Power rate</td>
<td>1600W</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>0 to 40°C</td>
</tr>
<tr>
<td>Storage humidity</td>
<td>20 to 85%</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>10 to 40°C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>20 to 80%</td>
</tr>
</tbody>
</table>