<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Analytical instrument &#8211; Phoenix Scientific Co., Ltd.</title>
	<atom:link href="https://phoenix-sci.com/product-category/all-categories/analytical-instrument/feed/" rel="self" type="application/rss+xml" />
	<link>https://phoenix-sci.com</link>
	<description>A Thailand’s leading provider in scientific and lab solutions.</description>
	<lastBuildDate>Thu, 24 Apr 2025 07:11:31 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://phoenix-sci.com/wp-content/uploads/2024/09/cropped-2025_LOGO-Phoenix-01-Photoroom-32x32.png</url>
	<title>Analytical instrument &#8211; Phoenix Scientific Co., Ltd.</title>
	<link>https://phoenix-sci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>K1100F Automatic Kjeldahl Analyzer</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/kjeldahl-system/k1100f-automatic-kjeldahl-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-kjeldahl-analyzer/</guid>

					<description><![CDATA[Hanon K1100F Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions and it is designed based on classic Kjeldahl nitrogen determination method. It's equipped with the latest core control system, powerful automation and high-quality components]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Automatic distillation, titration, calculation, printing, drain and cleaning function, safety and time-saving.</li>
<li>Visible titration cup design gives the operator real-time control of the whole test process.</li>
<li>Steam flow is controllable, satisfying different test requirements.</li>
<li>Regent tank enjoys fluid absence warning function, ensuring smooth test going.</li>
<li>High-precision charging pump and titration system ensure test results accuracy.</li>
<li>Large LCD touch screen gives visual operation, and enabling user to have a good command of it.</li>
<li>USB or RS485 interface is optional for PC connection.</li>
<li>Distilled liquid temperature is detected real-time. Emergency stop against temp anomaly.</li>
<li>Double distillation model meets different experiments, to retard the speed of acid-base reaction.</li>
<li>Digestion tube fast drain function is used to avoid operator touch distilled hot reagents, protecting operators.</li>
<li>The printer is built in.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center">Measuring range</td>
<td valign="center">0.1mg ～240mg N</td>
</tr>
<tr>
<td valign="center">Analysis time</td>
<td valign="center">5～10min/sample</td>
</tr>
<tr>
<td valign="center">Reproducibility</td>
<td valign="center">Average value relative error ±0.5%</td>
</tr>
<tr>
<td valign="center">Recovery</td>
<td valign="center">≧99.5%</td>
</tr>
<tr>
<td valign="center">Burette volume</td>
<td valign="center">1.0μL/step</td>
</tr>
<tr>
<td valign="center">Sample capacity</td>
<td valign="center">solid≦5g/sample, liquid≦20mL/sample</td>
</tr>
<tr>
<td valign="center">Water consumption in the distillation process</td>
<td valign="center">1.5L/min</td>
</tr>
<tr>
<td valign="center">Data storage capacity</td>
<td valign="center">1800 groups</td>
</tr>
<tr>
<td valign="center">Power supply</td>
<td valign="center">220VAC±10%, 50Hz</td>
</tr>
<tr>
<td valign="center">Power</td>
<td valign="center">2Kw</td>
</tr>
<tr>
<td valign="center">Net weight</td>
<td valign="center">38Kg</td>
</tr>
<tr>
<td valign="center">Dimensions</td>
<td valign="center">455mm×391mm×730mm</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Kjeldahl Protein/Nitrogen Analyzer</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/fully-automatic-system/automatic-kjeldahl-protein-nitrogen-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-kjeldahl-protein-nitrogen-analyzer/</guid>

					<description><![CDATA[Hanon K1160 Automatic Kjeldahl Protein/Nitrogen Analyzer is unique in its intelligence, efficiency, energy saving and data sharing, bringing more new experiences to users. The product can be widely used in the fields of food processing, feed production, tobacco, animal husbandry, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality supervision and other fields of nitrogen or protein determination.]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<ul>
<li>Automation, fully automatic distillation, titration, fault self-test, calculation, printing, waste disposal.</li>
<li>Can be paired with K1124 24-position autosampler.</li>
<li>Compliance with FDA 21CFR Part 11 and GMP.</li>
<li>High accuracy, burette accuracy can be adjust from 0.2 to 1μL/Step.</li>
</ul>
<p>&nbsp;</p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" /></colgroup>
<tbody>
<tr>
<td style="text-align: left;" colspan="2" rowspan="1"><strong>K1160 Kjeldahl Protein Analyzer</strong></td>
</tr>
<tr>
<td>Measuring range</td>
<td>0.1mg ～240mg N</td>
</tr>
<tr>
<td>Analysis time</td>
<td>3～8min/sample</td>
</tr>
<tr>
<td>Reproducibility</td>
<td>Average value relative error ±0.5%</td>
</tr>
<tr>
<td>Recovery</td>
<td>≧99.5%</td>
</tr>
<tr>
<td>Burette volume</td>
<td>
<div>
<div>1.0μL/step optional: 0.2μL/step and 0.4μL/step</div>
</div>
</td>
</tr>
<tr>
<td>Sample capacity</td>
<td>solid≦5g/sample, liquid≦20mL/sample</td>
</tr>
<tr>
<td>Water consumption in the distillation process</td>
<td>0.5L/min</td>
</tr>
<tr>
<td>Data storage capacity</td>
<td>1 million groups</td>
</tr>
<tr>
<td>Power supply</td>
<td>220VAC±10%, 50Hz</td>
</tr>
<tr>
<td>Power</td>
<td>2Kw</td>
</tr>
<tr>
<td>Net weight</td>
<td>38Kg</td>
</tr>
<tr>
<td>Dimensions</td>
<td>460mm×360mm×725mm</td>
</tr>
<tr>
<td style="text-align: left;" colspan="2" rowspan="1"><strong>K1124 Auto Sampler</strong></td>
</tr>
<tr>
<td>Capacity</td>
<td>24 samples per batch</td>
</tr>
<tr>
<td>Rotor speed</td>
<td>≥0.04r/s</td>
</tr>
<tr>
<td>Sampling speed</td>
<td>≥40mm/s</td>
</tr>
<tr>
<td>Tank capacity</td>
<td>4×15L</td>
</tr>
<tr>
<td>Connection</td>
<td>CAN</td>
</tr>
<tr>
<td>Voltage</td>
<td>24V DC</td>
</tr>
<tr>
<td>Rated Power</td>
<td>40W</td>
</tr>
<tr>
<td>Dimension(L×W×H)</td>
<td>920mm×625mm×908mm</td>
</tr>
<tr>
<td>Weight</td>
<td>80Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto Kjeldahl Distiller</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/kjeldahl-system/auto-kjeldahl-distiller/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/auto-kjeldahl-distiller/</guid>

					<description><![CDATA[The Hanon K9840 Auto Kjeldahl Distillation Unit is an advanced device for determining nitrogen content in samples using the Kjeldahl method. Ideal for applications in food processing, environmental monitoring, medicine, agriculture, and more.]]></description>
										<content:encoded><![CDATA[<p><strong>Key features:</strong></p>
<ul>
<li>4.3-inch color screen display</li>
<li>Manual/Automatic mode changeover</li>
<li>Automatic alkali pipeline washing function</li>
<li>Editable distillation time with automatic alarm upon completion</li>
<li>Intelligent cooling water control system</li>
<li>Emergency stop operation</li>
<li>Automatic fault detection with audible and visual alarm system</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center">Measuring range</td>
<td valign="center">0.1mg ～240mg N</td>
</tr>
<tr>
<td valign="center">Recovery</td>
<td valign="center">≧99.5%</td>
</tr>
<tr>
<td valign="center">Sample capacity</td>
<td valign="center">solid≦6g/sample, liquid≦16mL/sample</td>
</tr>
<tr>
<td valign="center">Distillation speed</td>
<td valign="center">3-6min/sample</td>
</tr>
<tr>
<td valign="center">Cooling water consumption</td>
<td valign="center">1.5L/min</td>
</tr>
<tr>
<td valign="center">Operating mode</td>
<td valign="center">Manual/automatic mode</td>
</tr>
<tr>
<td valign="center">Display modes</td>
<td valign="center">4.3&#8243; LCD screen</td>
</tr>
<tr>
<td valign="center">Power supply</td>
<td valign="center">220VAC±10%, 50Hz</td>
</tr>
<tr>
<td valign="center">Power</td>
<td valign="center">1.3KW</td>
</tr>
<tr>
<td valign="center">Net weight</td>
<td valign="center">30Kg</td>
</tr>
<tr>
<td valign="center">Dimensions</td>
<td valign="center">400mm×385mm×735mm</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>K9860 Automatic Kjeldahl Analyzer</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/kjeldahl-system/k9860-automatic-kjeldahl-analyzer-2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-kjeldahl-analyzer-2/</guid>

					<description><![CDATA[K9860 Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions, which is designed based on the classic Kjeldahl nitrogen determination method.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Automatic cleaning ensures operator safety and save time.</li>
<li>External titration cup design gives the operator real-time control of the whole test process.</li>
<li>High-precision charging pump and titration ensure test results accuracy.</li>
<li>The temperature of the distilled liquid is detected real-time. If the temperature of the distilled liquid is abnormal, to ensure the accuracy of experiment’s result, the instrument will stop working.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center">Measuring range</td>
<td valign="center">0.1mg ～240mg N</td>
</tr>
<tr>
<td valign="center">Analysis time</td>
<td valign="center">5～10min/sample</td>
</tr>
<tr>
<td valign="center">Reproducibility</td>
<td valign="center">Average value relative error ±0.5%</td>
</tr>
<tr>
<td valign="center">Recovery</td>
<td valign="center">≧99.5%</td>
</tr>
<tr>
<td valign="center">Burette volume</td>
<td valign="center">2.0μL/step</td>
</tr>
<tr>
<td valign="center">Sample capacity</td>
<td valign="center">solid≦5g/sample, liquid≦20mL/sample</td>
</tr>
<tr>
<td valign="center">Water consumption in the distillation process</td>
<td valign="center">1.5L/min</td>
</tr>
<tr>
<td valign="center">Data storage capacity</td>
<td valign="center">1000 groups</td>
</tr>
<tr>
<td valign="center">Power supply</td>
<td valign="center">220VAC±10%, 50Hz</td>
</tr>
<tr>
<td valign="center">Power</td>
<td valign="center">2Kw</td>
</tr>
<tr>
<td valign="center">Net weight</td>
<td valign="center">38Kg</td>
</tr>
<tr>
<td valign="center">Dimensions</td>
<td valign="center">455mm×391mm×730mm</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SH220F Kjeldahl Digestion System</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/kjeldahl-system/sh220f-kjeldahl-digestion-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/kjeldahl-digestion-system/</guid>

					<description><![CDATA[The SH220F has two temperature control modes: curve heating and linear temperature heating. It can edit and store 10 groups of digestion programs. Each group can set up a segment temperature and time gradient of up to 5 to meet different experimental needs of users.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>20 positions, enhance working efficiency rapidly.</li>
<li>Corrosion-resistant design.</li>
<li>It adopt advanced insulation technology, eco-friendly, reduce energy intensity maximum limitedly.</li>
<li>Multi-protection, Over-current protection, high temperature warning, overload protection.</li>
<li>LCD display.</li>
<li>It’s used with microwave reaction system, pretreat for microwave digestion or removing acid after digestion.</li>
<li>Linear and curve temperature rise mode, up to 5 stages temperature setting.</li>
<li>Curve temperature rise and linear temperature rise two temperature control modes.</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center" width="186">
<p align="center">
</td>
<td valign="center" width="235">
<p align="center">SH420F</p>
</td>
<td valign="center" width="167">
<p align="center">SH220F</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature range</td>
<td valign="center" width="225">Room temperature +5 &#8211; 450℃</td>
<td>
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature accuracy</td>
<td valign="center" width="225">±1℃</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating method</td>
<td valign="center" width="225">Infrared heating and high-purity graphite conduction</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating insulation method</td>
<td valign="center" width="225">Unique air duct insulation technology</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Digestion tube capacity</td>
<td valign="center" width="225">300mL</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Capacity per batch</td>
<td valign="center" width="225">20pcs/batch</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power supply</td>
<td valign="center" width="225">220 VAC±10% 50HZ</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power</td>
<td valign="center" width="225">3600W</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Dimensions</td>
<td valign="center" width="235">515mmX458mmX730mm</td>
<td valign="center" width="167">515mmX421mmX211mm</td>
</tr>
<tr>
<td valign="center" width="186">Net weight</td>
<td valign="center" width="235">40Kg</td>
<td valign="center" width="167">25Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SH420F Kjeldahl Digestion System</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/kjeldahl-system/sh420f-kjeldahl-digestion-system-2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/kjeldahl-digestion-system-2/</guid>

					<description><![CDATA[Hanon SH420F Kjeldahl Digestor adopts advanced high-temperature infrared radiation heating technology and microprocessor control platform, boasts accurate temperature control and quick temperature rise.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Can digest 20 samples at the same time</li>
<li>Using infrared radiation graphite conduction heating method, the heating speed is fast, and the temperature difference between the holes is small</li>
<li>Adopt PID temperature control technology, high temperature control accuracy, fast heating speed, only 25 minutes from room temperature to 400℃</li>
<li>2 heating methods: curve heating and linear heating, 500 groups of digestion programs can be edited and stored, and each group can be set up to 25 segments</li>
<li>Temperature and time gradient to meet different experimental needs of users</li>
<li>The surface of the instrument is coated with Teflon, and the whole machine is treated with anti-corrosion treatment to avoid the corrosion of the machine by acidic liquids during the experiment</li>
<li>Using 5.6 inch large screen true color LCD display system, intuitive and convenient operation</li>
<li>The whole machine has multiple protections such as over-voltage, over-current, over-heating, etc., and over-temperature alarm function</li>
<li>Adopt advanced ceramic and air duct heat insulation technology to make the experiment operation safer</li>
<li>Standard simple cooling rack, digestion tube can be cooled quickly, improve work efficiency</li>
<li>Optional waste gas neutralization system, through condensation, neutralization and drying to eliminate the acid gas generated during the experiment</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center" width="186">
<p align="center">
</td>
<td valign="center" width="235">
<p align="center">SH420F</p>
</td>
<td valign="center" width="167">
<p align="center">SH220F</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature range</td>
<td valign="center" width="225">Room temperature +5 &#8211; 450℃</td>
<td>
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature accuracy</td>
<td valign="center" width="225">±1℃</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating method</td>
<td valign="center" width="225">Infrared heating and high-purity graphite conduction</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating insulation method</td>
<td valign="center" width="225">Unique air duct insulation technology</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Digestion tube capacity</td>
<td valign="center" width="225">300mL</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Capacity per batch</td>
<td valign="center" width="225">20pcs/batch</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power supply</td>
<td valign="center" width="225">220 VAC±10% 50HZ</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power</td>
<td valign="center" width="225">3600W</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Dimensions</td>
<td valign="center" width="235">515mmX458mmX730mm</td>
<td valign="center" width="167">515mmX421mmX211mm</td>
</tr>
<tr>
<td valign="center" width="186">Net weight</td>
<td valign="center" width="235">40Kg</td>
<td valign="center" width="167">25Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Digestor (SH520/SH508)</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/automatic-digestor/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-digestor/</guid>

					<description><![CDATA[Fully automatic digestor adhering to the design concept of "reliable, intelligent and environmentally friendly", which can automatically complete the digestion process base on Kjeldahl method experiments.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristic:</strong></p>
<ul>
<li>Fully automatic operation, using Android system for controlling the lifting device and exhaust gas neutralization.</li>
<li>Options for 8 or 20 sample positions.</li>
<li>Aluminum deep-hole heating module for improved heating efficiency.</li>
<li>Real-time temperature monitoring and data storage.</li>
<li>Pre-installed and customizable digestion methods.</li>
<li>Energy-efficient design with ceramic and air duct heat insulation.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" />
<col width="189" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>SH520</strong></td>
<td style="text-align: center;"><strong>SH508</strong></td>
</tr>
<tr>
<td>Temperature Range</td>
<td>Room temperature +5°C~450C</td>
<td>Room temperature +5C~450C</td>
</tr>
<tr>
<td>Temperature accuracy</td>
<td>±1°℃</td>
<td>±1°℃</td>
</tr>
<tr>
<td>Heating Method</td>
<td>Electric heating tube</td>
<td>Electric heating tube</td>
</tr>
<tr>
<td>Digestion Tube</td>
<td>300mL</td>
<td>300mL / 380mL</td>
</tr>
<tr>
<td>Digestion Capacity</td>
<td>20 Positions</td>
<td>8 Positions</td>
</tr>
<tr>
<td>Lifting</td>
<td>Yes</td>
<td>Yes</td>
</tr>
<tr>
<td>Mainfold</td>
<td>Yes</td>
<td>Yes</td>
</tr>
<tr>
<td>Scrubber</td>
<td>Optional</td>
<td>Optional</td>
</tr>
<tr>
<td>Interface</td>
<td>WIFI / USB</td>
<td>WIFI / USB</td>
</tr>
<tr>
<td>Power Supply</td>
<td>AC 220±10%V(50±1)Hz</td>
<td>AC 220±10%V(50±1)Hz</td>
</tr>
<tr>
<td>Rated Power</td>
<td>2300W</td>
<td>1400W</td>
</tr>
<tr>
<td>Dimension (LxWxH)</td>
<td>305mm*590mm*151mm</td>
<td>328mm*440mm*151mm</td>
</tr>
<tr>
<td>Net Weight</td>
<td>21Kg</td>
<td>15Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-auto Fat Analyzer</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/fat-analyzer/semi-auto-fat-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/semi-auto-fat-analyzer/</guid>

					<description><![CDATA[Hanon SOX406 Fat Analyzer is based on the Soxhlet extraction principle and integrates such functions as soaking, extraction, leaching, heating, condensation and solvent recovery.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Integral metal heating, wide scope and high precision of temperature control.</li>
<li>Electric circuit is isolated from the extraction space, ensuring device security.</li>
<li>Timer and timing functions are available.</li>
<li>Over-temperature alarming and timer reminding functions are available.</li>
<li>Exclusive air insulation technique leaves the case in room temperature, has thermal insulation and temperature maintenance two functions.</li>
<li>4.3&#8243; LCD screen and microcomputer control system are adopted.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" /></colgroup>
<tbody>
<tr>
<td>Temperature range</td>
<td>Room temperature+5℃ ~ 280℃</td>
</tr>
<tr>
<td>Measuring range</td>
<td>0~100%</td>
</tr>
<tr>
<td>Temperature accuracy</td>
<td>±1℃</td>
</tr>
<tr>
<td>Sample weight</td>
<td>
<div>
<div>0.5~15g(generally 2 ~ 5g,depending on sample)</div>
</div>
</td>
</tr>
<tr>
<td>Capacity per batch</td>
<td>6pcs/batch</td>
</tr>
<tr>
<td>Solvent cup volume</td>
<td>80mL</td>
</tr>
<tr>
<td>Solvent recovery</td>
<td>≥80%</td>
</tr>
<tr>
<td>Shortened extraction time</td>
<td>20~80%</td>
</tr>
<tr>
<td>Power supply</td>
<td>220VAC±10%, 50Hz</td>
</tr>
<tr>
<td>Power</td>
<td>1KW</td>
</tr>
<tr>
<td>Dimensions</td>
<td>650mm×320mm×715mm</td>
</tr>
<tr>
<td>Net Weight</td>
<td>35Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Fat Analyzer</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/fat-analyzer/automatic-fat-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-fat-analyzer/</guid>

					<description><![CDATA[SOX606 Automatic Soxhlet Extractor, designed based on the Soxhlet extraction principle with weight method to determine the fat content.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Automatic extraction: One touch to start extraction, lifting, pre-heating, extraction, dilution, solvent recovery automatically.</li>
<li>In-built 5 unique methods of extraction, handy operation: Include Soxhlet Extraction, Soxhlet Hot Extraction, Continue Flow Extraction, Hot Extraction, CH Standard methods.</li>
<li>Apply to all organic solvents: Customized by glass and PTFE, which can block all impurities and possess high rate of accuracy, apply to all organic solvents, satisfying the requirements of users.</li>
<li>ECO- friendly and conservation: Full temperature and flow control for reduce consumption of condensed water.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" /></colgroup>
<tbody>
<tr>
<td>Temperature range</td>
<td>Room temperature +5℃~ 300℃</td>
</tr>
<tr>
<td>Measuring range</td>
<td>0.1~100%</td>
</tr>
<tr>
<td>Temperature accuracy</td>
<td>±1℃</td>
</tr>
<tr>
<td>Reproducibility</td>
<td>Relative error 1%</td>
</tr>
<tr>
<td>Sample weight</td>
<td>0.5~15g</td>
</tr>
<tr>
<td>Capacity per batch</td>
<td>6pcs/batch</td>
</tr>
<tr>
<td>Solvent cup volume</td>
<td>150mL</td>
</tr>
<tr>
<td>Solvent recovery</td>
<td>≥85%</td>
</tr>
<tr>
<td>Controller</td>
<td>External via cable</td>
</tr>
<tr>
<td>Power supply</td>
<td>220VAC±10%, 50Hz</td>
</tr>
<tr>
<td>Display</td>
<td>7 inches color touch screen</td>
</tr>
<tr>
<td>Power</td>
<td>2.6KW</td>
</tr>
<tr>
<td>Dimensions</td>
<td>650mmx380mmx720mm</td>
</tr>
<tr>
<td>Net Weight</td>
<td>50Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fiber Analyzer</title>
		<link>https://phoenix-sci.com/product/all-categories/analytical-instrument/protein-fat-fiber-analyzer/fiber-analyzer/fiber-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:03:49 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=9199</guid>

					<description><![CDATA[Hanon F800 Fiber Analyzer is with advanced design, easy operation and flexible application. It can be used in the conventional Weende method to analyze crude fiber and Van Soest analysis to wash the fiber. Applies to plant, feed, food and other agricultural products as well as the determination crude fiber, neutral detergent fiber (NDF), acid detergent fiber (ADF), hemicellulose and acid detergent lignin (ADL).]]></description>
										<content:encoded><![CDATA[<p><strong>Key features:</strong></p>
<ul>
<li><strong>Hidden Solution Barrel Pull Structure</strong>: Ensures safe fiber analysis by facilitating dosing operations.</li>
<li><strong>Crucible Recoil Function</strong>: Prevents sample caking during filtration.</li>
<li><strong>Dosing Overflow Protection</strong>: Protects operators from corrosive liquid overflow due to errors.</li>
<li><strong>Adjustable Crucible Heating Power</strong>: Allows easy control of heating rate, reducing energy consumption.</li>
<li><strong>Built-in Pre-heating Function</strong>: Significantly reduces experiment time.</li>
<li><strong>Various Crucible Specifications</strong>: Meets the needs of different samples.</li>
<li><strong>Advanced Integrated Infrared Heating</strong>: Provides uniform heating, consistent sample extraction, and higher extraction recovery.</li>
<li><strong>Versatile Analysis Capabilities</strong>: Can detect crude fiber, neutral detergent fiber (NDF), acid detergent fiber (ADF), hemicellulose, and acid detergent lignin (ADL).</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center" width="128">Measurement range</td>
<td valign="center" width="251">0.1%～100%</td>
</tr>
<tr>
<td valign="center" width="128">Sample weight</td>
<td valign="center" width="251">0.5g～3g</td>
</tr>
<tr>
<td valign="center" width="128">Repeatability error</td>
<td valign="center" width="251">Craw Fiber Content below 10%, ≤0.4%</p>
<p>Craw Fiber Content above 10%, ≤1%</td>
</tr>
<tr>
<td valign="center" width="128">Capacity</td>
<td valign="center" width="251">6 pcs/batch</td>
</tr>
<tr>
<td valign="center" width="128">Pre-heating time</td>
<td valign="center" width="251">10-12min</td>
</tr>
<tr>
<td valign="center" width="128">Heating to boiling</td>
<td valign="center" width="251">13-15min</td>
</tr>
<tr>
<td valign="center" width="128">Display</td>
<td valign="center" width="251">7 inches touch color screen</td>
</tr>
<tr>
<td valign="center" width="128">Rated power</td>
<td valign="center" width="251">2.2KW</td>
</tr>
<tr>
<td valign="center" width="128">Power supply</td>
<td valign="center" width="251">220 VAC ±10% 50Hz</td>
</tr>
<tr>
<td valign="center" width="128">Dimension</td>
<td valign="center" width="251">776mm×476mm×644mm</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
	</channel>