<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Raykol &#8211; Phoenix Scientific Co., Ltd.</title>
	<atom:link href="https://phoenix-sci.com/brands/raykol/feed/" rel="self" type="application/rss+xml" />
	<link>https://phoenix-sci.com</link>
	<description>A Thailand’s leading provider in scientific and lab solutions.</description>
	<lastBuildDate>Thu, 25 Jun 2026 03:20:13 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1</generator>

<image>
	<url>https://phoenix-sci.com/wp-content/uploads/2024/09/cropped-2025_LOGO-Phoenix-01-Photoroom-32x32.png</url>
	<title>Raykol &#8211; Phoenix Scientific Co., Ltd.</title>
	<link>https://phoenix-sci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Auto SPE-06D</title>
		<link>https://phoenix-sci.com/product/all-categories/automation/automated-spe/auto-spe-06d/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Thu, 24 Apr 2025 02:17:26 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24775</guid>

					<description><![CDATA[&#160; Both available in disk or column extraction This SPE equipment can simultaneously process 6 samples Built-in concentration module for nitrogen blowing Compact design for fume hood &#160; Parameter Specification Extraction channel 6 SPE disk size 47mm SPE cartridge size 3mL, 6mL Sample volume 10mL to 20L Solvent capacity 8 Software interface Windows PC; WIFI connection Voltage [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<ul>
<li>Both available in disk or column extraction</li>
<li>This SPE equipment can simultaneously process 6 samples</li>
<li>Built-in concentration module for nitrogen blowing</li>
<li>Compact design for fume hood</li>
</ul>
<p>&nbsp;</p>
<div class="overflow-x">
<table width="381" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td class="et3" width="175" height="15"><strong>Parameter</strong></td>
<td class="et4" width="206"><strong>Specification</strong></td>
</tr>
<tr>
<td class="et5" width="175" height="15">Extraction channel</td>
<td class="et5" width="206">6</td>
</tr>
<tr>
<td class="et5" width="175" height="15">SPE disk size</td>
<td class="et5" width="206">47mm</td>
</tr>
<tr>
<td class="et5" width="175" height="15">SPE cartridge size</td>
<td class="et5" width="206">3mL, 6mL</td>
</tr>
<tr>
<td class="et6" width="175" height="15">Sample volume</td>
<td class="et6" width="206">10mL to 20L</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Solvent capacity</td>
<td class="et5" width="206">8</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Software interface</td>
<td class="et5" width="206">Windows PC; WIFI connection</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Voltage</td>
<td class="et5" width="206">200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Operating temperature</td>
<td class="et5" width="206">10 to 40°C</td>
</tr>
<tr>
<td class="et5" width="175" height="15">Operating humidity</td>
<td class="et5" width="206">20 to 80%</td>
</tr>
</tbody>
</table>
</div>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MTV 3000 Multi-Tube Vortex Mixer</title>
		<link>https://phoenix-sci.com/product/all-categories/general-laboratory-equipment/vortex-mixer/mtv-3000-multi-tube-vortex-mixer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 23 Apr 2025 03:05:13 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24620</guid>

					<description><![CDATA[An ideal mixer for large sample batches, RayKol MTV 3000 is mainly used for vortex mixing up to 66 samples.]]></description>
										<content:encoded><![CDATA[<div style="width: 800px;" class="wp-video"><video class="wp-video-shortcode" id="video-24620-1" width="800" height="450" preload="metadata" controls="controls"><source type="video/mp4" src="https://phoenix-sci.com/wp-content/uploads/2025/09/Vortex-Mixer.mp4?_=1" /><a href="https://phoenix-sci.com/wp-content/uploads/2025/09/Vortex-Mixer.mp4">https://phoenix-sci.com/wp-content/uploads/2025/09/Vortex-Mixer.mp4</a></video></div>
<p>&nbsp;</p>
<p>High throughput, wide application range, and simple operation</p>
<ul>
<li>7-inch color touch screen control, real-time display of the current rate and remaining time</li>
<li>Appointment start, cycle setting, multiple steps of different rate and duration</li>
<li>Available in 3 modes for operation for various sample matrices</li>
<li>High throughput, can process up to 66 samples simultaneously</li>
<li>Compatible with 100 mL, 50 mL and 15 mL vials, also available in customized racks</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>XT-iMD Series Microwave Digestion System</title>
		<link>https://phoenix-sci.com/product/all-categories/sample-preparation/microwave-and-block-digestion/16/xt-imd-series-microwave-digestion-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 04:15:29 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=23947</guid>

					<description><![CDATA[An efficient and user-friendly microwave digestion system with high throughput and multiple safety measures.]]></description>
										<content:encoded><![CDATA[<ul class="custom_dot list-paddingleft-1">
<li class="list-dot list-dot-paddingleft">High efficiency by rapid heating and uniform microwave</li>
<li class="list-dot list-dot-paddingleft">Batch microwave digestion, up to 24 or 40 samples at once</li>
<li class="list-dot list-dot-paddingleft">Touch screen control, user-friendly interface</li>
<li class="list-dot list-dot-paddingleft">Multiply safety measures for user and instrument protection</li>
<li class="list-dot list-dot-paddingleft">Convenient design in sample loading</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td height="15"><strong>Parameter</strong></td>
<td colspan="2"><strong>Specification</strong></td>
</tr>
<tr>
<td height="15">Sample capacity</td>
<td>42</td>
<td>16</td>
</tr>
<tr>
<td height="15">Digestion vessel</td>
<td>High-throughput, 75mL</td>
<td>High-pressure, 100mL</td>
</tr>
<tr>
<td height="15">Microwave cavity</td>
<td colspan="2">65L</td>
</tr>
<tr>
<td height="15">Microwave power</td>
<td colspan="2">2400W</td>
</tr>
<tr>
<td height="15">Temperature monitor</td>
<td colspan="2">Mid-infrared contactless sensor</td>
</tr>
<tr>
<td height="15">Pressure release</td>
<td colspan="2">Automatic pressure-release mechanism</td>
</tr>
<tr>
<td height="15">Dimension</td>
<td colspan="2">600mm x 650mm x 755mm</td>
</tr>
<tr>
<td height="15">Weight</td>
<td colspan="2">70kg</td>
</tr>
<tr>
<td height="15">Power supply</td>
<td colspan="2">220V AC, 50/60Hz</td>
</tr>
<tr>
<td height="15">Input power</td>
<td colspan="2">3000W</td>
</tr>
<tr>
<td height="30">Fume hood/ventilation</td>
<td colspan="2">Required</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>XT-9930 Microwave Digestion System</title>
		<link>https://phoenix-sci.com/product/all-categories/sample-preparation/microwave-and-block-digestion/16/xt-9930-microwave-digestion-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 04:15:29 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=23949</guid>

					<description><![CDATA[High-performance microwave digestion system with high throughput and flexibility]]></description>
										<content:encoded><![CDATA[<ul class=" list-paddingleft-2">
<li>Batch digestion up to 42 samples</li>
<li>75L industrial 316L stainless steel cylinder chamber</li>
<li>Mid-infrared temperature monitoring</li>
<li>Non-contact pressure sensor with pressure relief</li>
<li>Able to detect digestion rotor type</li>
<li>Comprehensive safety protection</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td height="15"><strong>Parameter</strong></td>
<td colspan="2"><strong>Specification</strong></td>
</tr>
<tr>
<td height="15">Sample capacity</td>
<td>42</td>
<td>16</td>
</tr>
<tr>
<td height="15">Digestion vessel</td>
<td>High-throughput, 75mL</td>
<td>High-pressure, 100mL</td>
</tr>
<tr>
<td height="15">Microwave cavity</td>
<td colspan="2">75L</td>
</tr>
<tr>
<td height="15">Microwave power</td>
<td colspan="2">2400W</td>
</tr>
<tr>
<td height="15">Temperature monitor</td>
<td colspan="2">Mid-infrared contactless sensor</td>
</tr>
<tr>
<td height="15">Pressure release</td>
<td colspan="2">Automatic pressure-release mechanism</td>
</tr>
<tr>
<td height="15">Dimension</td>
<td colspan="2">650mm x 630mm x 620mm</td>
</tr>
<tr>
<td height="15">Weight</td>
<td colspan="2">70kg</td>
</tr>
<tr>
<td height="15">Power supply</td>
<td colspan="2">220V AC, 50/60Hz</td>
</tr>
<tr>
<td height="15">Input power</td>
<td colspan="2">3000W</td>
</tr>
<tr>
<td height="30">Fume hood/ventilation</td>
<td colspan="2">Required</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>XT-9910 Microwave Digestion System</title>
		<link>https://phoenix-sci.com/product/all-categories/sample-preparation/microwave-and-block-digestion/8-microwave-digestion/xt-9910-microwave-digestion-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 04:15:29 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=23953</guid>

					<description><![CDATA[A compact and economical microwave digestion solution]]></description>
										<content:encoded><![CDATA[<ul class=" list-paddingleft-2">
<li>Compact design</li>
<li>Specialized for small batch processing</li>
<li>Comprehensive safety measures</li>
<li>Max. working pressure is 5 Mpa</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td height="15"><strong>Parameter</strong></td>
<td colspan="2"><strong>Specification</strong></td>
</tr>
<tr>
<td height="15">Sample capacity</td>
<td colspan="2">8</td>
</tr>
<tr>
<td height="15">Digestion vessel</td>
<td colspan="2">High-pressure, 100mL</td>
</tr>
<tr>
<td height="15">Microwave cavity</td>
<td colspan="2">35L</td>
</tr>
<tr>
<td height="15">Microwave power</td>
<td colspan="2">1000W</td>
</tr>
<tr>
<td height="15">Temperature monitor</td>
<td colspan="2">Mid-infrared contactless sensor</td>
</tr>
<tr>
<td height="15">Pressure release</td>
<td colspan="2">Explosion-proof membrane</td>
</tr>
<tr>
<td height="15">Dimension</td>
<td colspan="2">610mm x 500mm x 550mm</td>
</tr>
<tr>
<td height="15">Weight</td>
<td colspan="2">40kg</td>
</tr>
<tr>
<td height="15">Power supply</td>
<td colspan="2">220V AC, 50/60Hz</td>
</tr>
<tr>
<td height="15">Input power</td>
<td colspan="2">1500W</td>
</tr>
<tr>
<td height="30">Fume hood/ventilation</td>
<td colspan="2">Required</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SPEva Automated SPE &#038; Evaporation System</title>
		<link>https://phoenix-sci.com/product/all-categories/automation/automated-spe/speva-automated-spe-evaporation-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 03:29:20 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24210</guid>

					<description><![CDATA[SPEVA is designed to integrate solid phase extraction and nitrogen evaporation processes. It automatically completes the steps of conditioning, sample loading, rinsing, drying and elution, while continuously evaporating and solvent replacement of the eluent and then passing through the cartridge again.]]></description>
										<content:encoded><![CDATA[<p><iframe title="SPEVA Automated Sample purification and Concentration System" width="800" height="450" src="https://www.youtube.com/embed/CH-pCHJ3SvE?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<ul>
<li>Able to load samples via needles, pipettes, large-volume kit</li>
<li>Simultaneously process 6 samples</li>
<li>SPE and nitrogen blowing in one system</li>
<li>User-friendly software</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td width="178"><strong>Parameter</strong></td>
<td width="351"><strong>Specification</strong></td>
</tr>
<tr>
<td width="178">Extraction channel</td>
<td width="351">6</td>
</tr>
<tr>
<td width="178">SPE cartridge size</td>
<td width="351">3mL, 6mL</td>
</tr>
<tr>
<td width="313">Sample volume</td>
<td width="351">10mL to 20L</td>
</tr>
<tr>
<td width="178">Solvent capacity</td>
<td width="351">8</td>
</tr>
<tr>
<td width="178">Software interface</td>
<td width="351">Windows PC; WIFI connection</td>
</tr>
<tr>
<td width="178">Voltage</td>
<td width="351">200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td width="178">Operating temperature</td>
<td width="351">10 to 40°C</td>
</tr>
<tr>
<td width="178">Operating humidity</td>
<td width="351">20 to 80%</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Fotector Series Automated SPE Systems</title>
		<link>https://phoenix-sci.com/product/all-categories/automation/automated-spe/fotector-series-automated-spe-systems/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 03:22:40 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24201</guid>

					<description><![CDATA[&#160; Fully automated solid-phase extraction, minimal operator intervention Accurate flow rate control to ensure parallelism Multiple extraction channels, consistent batch processing Efficient operation mode through sychronous rack positioning and fast solvent switch Flexible operation with various modules for different applications Graphical software interface, remote real-time monitoring &#160; Parameter Specification Product Fotector 02HT Fotector Plus Fotector [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><iframe title="RayKol Fotector series Automated Solid Phase Extraction System / Automated SPE System" width="800" height="450" src="https://www.youtube.com/embed/Z7aqPlfvUJo?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<ul>
<li>Fully automated solid-phase extraction, minimal operator intervention</li>
<li>Accurate flow rate control to ensure parallelism</li>
<li>Multiple extraction channels, consistent batch processing</li>
<li>Efficient operation mode through sychronous rack positioning and fast solvent switch</li>
<li>Flexible operation with various modules for different applications</li>
<li>Graphical software interface, remote real-time monitoring</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td><strong>Parameter</strong></td>
<td style="text-align: center;" colspan="4"><strong>Specification</strong></td>
</tr>
<tr>
<td>Product</td>
<td>Fotector 02HT</td>
<td>Fotector Plus</td>
<td>Fotector 08HT</td>
<td>FS 360</td>
</tr>
<tr>
<td>Extraction channel</td>
<td>2 channels in parallel</td>
<td>6 channels in parallel</td>
<td>8 channels in parallel</td>
<td>6 channels in parallel</td>
</tr>
<tr>
<td>Sample capacity</td>
<td>20, 12</td>
<td>60, 36</td>
<td>80, 48</td>
<td>36</td>
</tr>
<tr>
<td>SPE cartridge size</td>
<td>3mL, 6mL</td>
<td>1mL, 3mL, 6mL, 12mL, 20mL</td>
<td>1mL, 3mL, 6mL</td>
<td>3mL, 6mL, 12mL</td>
</tr>
<tr>
<td>Sample vials</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 80mL</td>
</tr>
<tr>
<td>Collection vials</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 60mL, 80mL</td>
<td>15mL, 20mL, 80mL</td>
</tr>
<tr>
<td>Solvent capacity</td>
<td>8</td>
<td>8</td>
<td>8</td>
<td>8</td>
</tr>
<tr>
<td>Flow rate</td>
<td>0.1 to 100mL/min</td>
<td>0.1 to 100mL/min</td>
<td>0.1 to 100mL/min</td>
<td>0.1 to 100mL/min</td>
</tr>
<tr>
<td>Gas supply and connection</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
<td>Nitrogen gas;<br />
Max. input: 100psi/6.9bar;<br />
Output: 0 to 20psi/1.4bar</td>
</tr>
<tr>
<td>Fume hood/ventilation</td>
<td>Required</td>
<td>Required</td>
<td>Required</td>
<td>Required</td>
</tr>
<tr>
<td>Control software</td>
<td>Windows PC; WIFI connection</td>
<td>Windows PC; WIFI connection</td>
<td>Windows PC; WIFI connection</td>
<td>Windows PC; WIFI connection</td>
</tr>
<tr>
<td>Dimension</td>
<td>40cm x 38cm x 58cm</td>
<td>62cm x 38cm x 63cm</td>
<td>77cm x 45cm x 64cm</td>
<td>62cm x 38cm x 63cm</td>
</tr>
<tr>
<td>Weight</td>
<td>30kg</td>
<td>68kg</td>
<td>72kg</td>
<td>68kg</td>
</tr>
<tr>
<td>Power supply</td>
<td>200 to 240V, 50/60Hz</td>
<td>200 to 240V, 50/60Hz</td>
<td>200 to 240V, 50/60Hz</td>
<td>200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>0 to 40°C</td>
<td>0 to 40°C</td>
<td>0 to 40°C</td>
<td>0 to 40°C</td>
</tr>
<tr>
<td>Storage humidity</td>
<td>20 to 85%</td>
<td>20 to 85%</td>
<td>20 to 85%</td>
<td>20 to 85%</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>10 to 40°C</td>
<td>10 to 40°C</td>
<td>10 to 40°C</td>
<td>10 to 40°C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>20 to 80%</td>
<td>20 to 80%</td>
<td>20 to 80%</td>
<td>20 to 80%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DRQ Automated QuEChERS Extraction</title>
		<link>https://phoenix-sci.com/product/all-categories/automation/quechers-extraction/drq-automated-quechers-extraction/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Fri, 18 Apr 2025 03:19:57 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=24198</guid>

					<description><![CDATA[RayKol DRQ Automated QuEChERS Extraction System is an innovation benchtop automated sample preparation system specialized in QuEChERS method. The compact and hooded design makes it free the fume hood space and easy to position. It does not require any manual involvement after sample weighing, applicable to any automated QuEChERS methods required steps of liquid dispensing, [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><iframe title="HUI BIAO Testing-DRQ Automated QuEChERS Extraction System" width="800" height="450" src="https://www.youtube.com/embed/f63-Lsbl0r0?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>RayKol DRQ Automated QuEChERS Extraction System is an innovation benchtop automated sample preparation system specialized in QuEChERS method. The compact and hooded design makes it free the fume hood space and easy to position. It does not require any manual involvement after sample weighing, applicable to any automated QuEChERS methods required steps of liquid dispensing, shaking, centrifugation, and separation.</p>
<ul class=" list-paddingleft-2">
<li>Batch continuously processing, max. 48 samples</li>
<li>Fullly automated QuEChERS method</li>
<li>Efficient dual-channel capping design</li>
<li>Compact benchtop design</li>
</ul>
<p>&nbsp;</p>
<table width="525" cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td class="et4" width="139" height="15"><strong>Parameter</strong></td>
<td class="et5" width="386"><strong>Specification</strong></td>
</tr>
<tr>
<td class="et6" width="139" height="15">Sample capacity</td>
<td class="et7" width="386">Max. 48 samples</td>
</tr>
<tr>
<td class="et8" width="139" height="15">Sample tube</td>
<td class="et9" width="386">50mL/15mL centrifuge vial</td>
</tr>
<tr>
<td class="et10" width="139" height="15">Software interface</td>
<td class="et11" width="386">Built-in screen</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto EVA Mini Automated Parallel Nitrogen Evaporator</title>
		<link>https://phoenix-sci.com/product/all-categories/sample-preparation/nitrogen-evaporator/24/auto-eva-mini-automated-parallel-nitrogen-evaporator/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Thu, 17 Apr 2025 04:39:44 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=23987</guid>

					<description><![CDATA[Solutions for sample volume less than 5mL]]></description>
										<content:encoded><![CDATA[<ul class=" list-paddingleft-2">
<li>Batch concentration for small-volume samples</li>
<li>Accurate and flexible in gas flow rate control</li>
<li>Good compatibility, variety of accessories</li>
<li>Smart and graphical software control</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignnone  wp-image-27869" src="https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2.webp" alt="" width="689" height="787" srcset="https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2.webp 1190w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-263x300.webp 263w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-897x1024.webp 897w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-768x877.webp 768w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-600x685.webp 600w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-64x73.webp 64w" sizes="auto, (max-width: 689px) 100vw, 689px" /></p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td><strong>Parameter</strong></td>
<td><strong>Specification</strong></td>
</tr>
<tr>
<td>Concentration</td>
<td>Nitrogen blowing and sample rack heating</td>
</tr>
<tr>
<td>Nitrogen channel</td>
<td>4</td>
</tr>
<tr>
<td>Sample capacity</td>
<td>24, 96</td>
</tr>
<tr>
<td>Sample vials</td>
<td>2mL/5mL centrifuge vials, 2mL GC vial, 96-well microplate</td>
</tr>
<tr>
<td>Range of flow rate</td>
<td>0 to 3.0L/min, precise to 0.1L/min</td>
</tr>
<tr>
<td>Temperature range of sample rack</td>
<td>Room temperature to 100°C, precise to 0.1°C</td>
</tr>
<tr>
<td>Temperature range of nitrogen gas flow</td>
<td>Room temperature to 70°C</td>
</tr>
<tr>
<td>Software interface</td>
<td>7-inch built-in touch screen</td>
</tr>
<tr>
<td>Dimension</td>
<td>47cm x 25cm x 43cm</td>
</tr>
<tr>
<td>Weight</td>
<td>21kg</td>
</tr>
<tr>
<td>Power supply</td>
<td>200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td>Power rate</td>
<td>1000W</td>
</tr>
<tr>
<td>Fume hood/ventilation</td>
<td>Required</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>0 to 40°C</td>
</tr>
<tr>
<td>Storage humidity</td>
<td>20 to 85%</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>10 to 40°C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>20 to 80%</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Auto EVA 80 Automated Parallel Nitrogen Evaporator</title>
		<link>https://phoenix-sci.com/product/all-categories/sample-preparation/nitrogen-evaporator/48/auto-eva-80-automated-parallel-nitrogen-evaporator/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Thu, 17 Apr 2025 04:39:36 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=23985</guid>

					<description><![CDATA[Upgraded from the features of Auto EVA series, evaporation up to 80 samples]]></description>
										<content:encoded><![CDATA[<p><iframe loading="lazy" title="RayKol Auto EVA 80 Automated Parallel Evaporator | Expert Nitrogen Blow-Down Experience" width="800" height="450" src="https://www.youtube.com/embed/ye4IoTUUlaU?feature=oembed&#038;enablejsapi=1&#038;origin=https://phoenix-sci.com" frameborder="0" allow="accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share" referrerpolicy="strict-origin-when-cross-origin" allowfullscreen></iframe></p>
<p>&nbsp;</p>
<ul class="custom_dot list-paddingleft-1">
<li class="list-dot list-dot-paddingleft">Batch evaporation up to 80 samples</li>
<li class="list-dot list-dot-paddingleft">Integration of product features from Auto EVA 60</li>
<li class="list-dot list-dot-paddingleft">Transparent sink design for clear observation</li>
<li class="list-dot list-dot-paddingleft">Built-in touch screen, direct software control</li>
<li class="list-dot list-dot-paddingleft">Compact design with high throughput</li>
</ul>
<p><img loading="lazy" decoding="async" class="alignnone  wp-image-27869" src="https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2.webp" alt="" width="736" height="840" srcset="https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2.webp 1190w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-263x300.webp 263w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-897x1024.webp 897w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-768x877.webp 768w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-600x685.webp 600w, https://phoenix-sci.com/wp-content/uploads/2025/04/EVA-Comparison-2-64x73.webp 64w" sizes="auto, (max-width: 736px) 100vw, 736px" /></p>
<table cellspacing="0" cellpadding="0">
<tbody>
<tr class="firstRow">
<td><strong>Parameter</strong></td>
<td><strong>Specification</strong></td>
</tr>
<tr>
<td>Concentration</td>
<td>Water bath heating and nitrogen blowing</td>
</tr>
<tr>
<td>Nitrogen channel</td>
<td>8</td>
</tr>
<tr>
<td>Sample capacity</td>
<td>80, 48</td>
</tr>
<tr>
<td>Sample vials</td>
<td>10 to 100mL</td>
</tr>
<tr>
<td>Range of flow rate</td>
<td>0 to 3.0L/min, precise to 0.1L/min</td>
</tr>
<tr>
<td>Software interface</td>
<td>10 inch built-in touch screen</td>
</tr>
<tr>
<td>Dimension</td>
<td>40cm x 48cm x 54cm</td>
</tr>
<tr>
<td>Weight</td>
<td>48kg</td>
</tr>
<tr>
<td>Power supply</td>
<td>200 to 240V, 50/60Hz</td>
</tr>
<tr>
<td>Power rate</td>
<td>1500W</td>
</tr>
<tr>
<td>Fume hood/ventilation</td>
<td>Required</td>
</tr>
<tr>
<td>Storage temperature</td>
<td>0 to 40°C</td>
</tr>
<tr>
<td>Storage humidity</td>
<td>20 to 85%</td>
</tr>
<tr>
<td>Operating temperature</td>
<td>10 to 40°C</td>
</tr>
<tr>
<td>Operating humidity</td>
<td>20 to 80%</td>
</tr>
</tbody>
</table>