<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>MSR-Electronic &#8211; Phoenix Scientific Co., Ltd.</title>
	<atom:link href="https://phoenix-sci.com/brands/msr-electronic/feed/" rel="self" type="application/rss+xml" />
	<link>https://phoenix-sci.com</link>
	<description>A Thailand’s leading provider in scientific and lab solutions.</description>
	<lastBuildDate>Thu, 17 Apr 2025 08:14:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://phoenix-sci.com/wp-content/uploads/2024/09/cropped-2025_LOGO-Phoenix-01-Photoroom-32x32.png</url>
	<title>MSR-Electronic &#8211; Phoenix Scientific Co., Ltd.</title>
	<link>https://phoenix-sci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Multi-Sensor-Controller MSC2</title>
		<link>https://phoenix-sci.com/product/multi-sensor-controller-msc2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Thu, 17 Apr 2025 08:14:43 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12563</guid>

					<description><![CDATA[The Multi-Sensor-Controller MSC2 monitors the measured values and activates the alarm relays if the preset alarm thresholds for pre-alarm and main alarm are exceeded. Various output and input options enable easy integration into existing systems. The sensors are connected to the MSC2 directly on the board. Up to 2 (different) digital sensors can be connected or [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>The Multi-Sensor-Controller MSC2 monitors the measured values and activates the alarm relays if the preset alarm thresholds for pre-alarm and main alarm are exceeded. Various output and input options enable easy integration into existing systems. The sensors are connected to the MSC2 directly on the board. Up to 2 (different) digital sensors can be connected or 2 analog sensors can be connected remotely. In total the MSC2 can process up to 3 sensors and therefore represents a small, compact version with many possible applications.</p>
<p><strong>Benefits</strong></p>
<ul>
<li>Modular design</li>
<li>Compatible with a wide range of BMS</li>
<li>Personal contact person at MSR-Electronic</li>
<li>Device can be used independently of control center, stand-alone devices without DGC-06</li>
<li>System can be expanded at any time, can grow modularly</li>
<li>Individual parameterization possible</li>
<li>Display / UPS (optional)</li>
<li>X-Change technology for safe and simple sensor replacement without prior knowledge</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Digital-Gas-Controller DGC-06</title>
		<link>https://phoenix-sci.com/product/digital-gas-controller-dgc-06/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 04:27:21 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12596</guid>

					<description><![CDATA[The gas monitoring center. Measuring, warning and controlling device system in different versions. Applicable for large systems for monitoring and evaluation of up to 128 sensors and control of up to 32 relays.]]></description>
										<content:encoded><![CDATA[<p>The Digital-Gas-Controller DGC-06 has been developed for large systems or for extensive connections. There is hardly a scenario in gas monitoring that this controller does not cover. From complex garages to access functions that are activated by gas alarm, everything is possible. The innovative DGC-06 gas controller series is designed in accordance with EN 50545 and other standards and can monitor and evaluate up to 128 gas sensors, including 96 digital and/or 32 analog sensors (4-20 mA).</p>
<p>There are 4 freely adjustable alarm thresholds per sensor. For alarm messages, the controller system has up to 32 relays with potential-free changeover contact and up to 16 analog outputs with 4-20 mA signal.</p>
<p><strong>Benefits</strong></p>
<ul>
<li>Modular design</li>
<li>Compatible with a wide range of BMS</li>
<li>System can be expanded at any time, can grow modularly</li>
<li>Individual parameterization possible</li>
<li>Large controller that can be adapted to any situation thanks to its modular design</li>
<li>Personal contact at MSR-Electronic</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Door-Entrance-Modul DEM-06</title>
		<link>https://phoenix-sci.com/product/door-entrance-modul-dem-06/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 04:23:59 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12593</guid>

					<description><![CDATA[Visualizes the gas alarm in real time at all access points.]]></description>
										<content:encoded><![CDATA[<p>The DEM-06 Door-Entrance-Modules from MSR-Electronic ensure maximum safety. If an increased gas concentration occurs in buildings, e.g. in parking garages, the entrances can only be opened in one direction: From the inside to the outside. This ensures that people can only move outwards from the hazardous area, but never inwards.</p>
<p><strong>Benefits</strong></p>
<ul>
<li>Visual and audible warning</li>
<li>For buildings with different danger zones</li>
<li>Stand-alone application with fieldbus information (without DGC controller) possible</li>
<li>No intervention in the DGC controller system necessary</li>
<li>Configurable for up to 96 sensors in one DGC controller system</li>
<li>Personal contact at MSR-Electronic</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Analog sensor (MC2)</title>
		<link>https://phoenix-sci.com/product/analog-sensor-mc2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 04:21:23 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12591</guid>

					<description><![CDATA[Analog changeover sensor with 4-20 mA / 2-10 V output and simple, integrated, digital calibration routine using a tool.]]></description>
										<content:encoded><![CDATA[<p>MSR-Electronic develops individual gas sensors, e.g. for CO2, CO, CH4, CH2O, NH3, O2 or H2 and systems that monitor toxic or combustible gas concentrations.</p>
<p>The innovative sensors are integrated into complex warning systems and are used, for example, in parking garages, biogas plants, refrigeration plants, petrochemical industrial plants, breweries and dispensing systems or in laboratories and medical applications as well as in hydrogen production and processing.</p>
<p>In addition to the sensor element and the measuring amplifier, the SC2 and MC2 sensors include a μController for measured value processing. Thus, various data can be processed and utilized, such as the temperature for compensation of the measured value. In addition, calibration interval and errors are monitored and transmitted to the evaluation unit.</p>
<p>Thanks to the X-Change technology, calibration can be performed by simply changing the sensor head or by using the integrated, convenient calibration routine directly at the system.</p>
<p>The sensors are designed for connection to MSR-Electronic controllers and boards.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Digital sensor (SC2)</title>
		<link>https://phoenix-sci.com/product/digital-sensor-sc2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 04:17:44 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12589</guid>

					<description><![CDATA[Digital exchangeable sensor with local bus, outputs information on calibration interval and service life in addition to the measured value. Digital signature of the sensor for clear assignment to the connected board.]]></description>
										<content:encoded><![CDATA[<p>MSR-Electronic develops individual gas sensors, e.g. for CO2, CO, CH4, CH2O, NH3, O2 or H2 and systems that monitor toxic or combustible gas concentrations.</p>
<p>The innovative sensors are integrated into complex warning systems and are used, for example, in parking garages, biogas plants, refrigeration plants, petrochemical industrial plants, breweries and dispensing systems or in laboratories and medical applications as well as in hydrogen production and processing.</p>
<p>In addition to the sensor element and the measuring amplifier, the SC2 and MC2 sensors include a μController for measured value processing. Thus, various data can be processed and utilized, such as the temperature for compensation of the measured value. In addition, calibration interval and errors are monitored and transmitted to the evaluation unit.</p>
<p>Thanks to the X-Change technology, calibration can be performed by simply changing the sensor head or by using the integrated, convenient calibration routine directly at the system.</p>
<p>The sensors are designed for connection to MSR-Electronic controllers and boards.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Warning and Sensor-Board WSB2</title>
		<link>https://phoenix-sci.com/product/warning-and-sensor-board-wsb2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 03:49:17 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12587</guid>

					<description><![CDATA[With RS-485 interface, 4-20 mA output and alarm relay.]]></description>
										<content:encoded><![CDATA[<p>The WSB2 warning and sensor-board ensures the power supply to the sensors and prepares the measured data of the sensor head for digital communication.</p>
<p>Communication with the DGC-06 controller takes place via the RS-485 fieldbus interface with DGC-06 protocol. The sensor head is connected to the local bus via a plug connection. This enables a simple sensor head exchange instead of an on-site calibration. The internal X-Change routine recognizes the exchanged sensor head during the change process and starts the measuring operation automatically.</p>
<p><strong>Benefits</strong></p>
<ul>
<li>Modular design</li>
<li>Compatible with a wide range of BMS</li>
<li>Simple handling, no separate tool required</li>
<li>Personal contact at MSR-Electronic</li>
<li>Device can be used independently of control center, stand-alone devices without DGC-06</li>
<li>System can be expanded at any time, can grow modularly</li>
<li>Individual parameterization possible</li>
<li>Robust against dust, humidity and high/low temperatures</li>
<li>Ideal for heating or cooling applications</li>
<li>X-Change technology for safe and easy sensor replacement without prior knowledge</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Digital Sensor Head SSAX1</title>
		<link>https://phoenix-sci.com/product/digital-sensor-head-ssax1/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 03:21:08 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12581</guid>

					<description><![CDATA[The ATEX sensor head for remote applications.]]></description>
										<content:encoded><![CDATA[<p>In addition to the high-quality sensor element and the measuring amplifier, the SSAX1 sensor head includes a μController for processing the measured values. All relevant data and measured values of the sensor element are stored in the μController in a fail-safe manner and are transmitted digitally via the local bus to the WSB2/MSC2 or PX2 via the local bus. Calibration management is also integrated in the μController of the sensor head. Calibration can be carried out by simply changing the sensor head or using the integrated, convenient calibration routine directly on the system.</p>
<p>The SSAX1 is connected directly to the PX2 and can therefore be used as a complete device in the ATEX zone. In addition, the ATEX-certified sensor head SSAX1 can also be connected to a WSB2/MSC2 or PX2 (which are installed outside the danger zone) on its own in the danger zone with the corresponding ATEX cable in order to evaluate the sensor there.</p>
<p><strong>Benefits</strong></p>
<ul>
<li>ATEX and IECEx certificates for electrical explosion protection</li>
<li>SSAX1 for zone 1 (also applicable in zone 2): Version &#8220;Ex db&#8221; with flameproof enclosure</li>
<li>Different measuring principles depending on customer requirements and application: Infrared, electrochemical sensor, pellistor, MPS™</li>
<li>High accuracy, selectivity and reliability</li>
<li>Easy calibration</li>
<li>Personal contact at MSR-Electronic</li>
</ul>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PolyXeta® PX2 With Sensor Head SX1</title>
		<link>https://phoenix-sci.com/product/polyxeta-px2-with-sensor-head-sx1/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 02 Apr 2025 03:11:20 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=12577</guid>

					<description><![CDATA[PX2 with Sensor Head SX1 With X-Change Technology]]></description>
										<content:encoded><![CDATA[<ul>
<li>4-20 mA and RS-485-Modbus output</li>
<li>Suitable for connection to GC-06</li>
<li>2 relay outputs for alarm and fault relays</li>
<li>Optional LC display</li>
</ul>
<p>&nbsp;</p>
<p><strong>Benefits</strong></p>
<ul>
<li>Modular design</li>
<li>Compatible with a wide range of BMS</li>
<li>Personal contact person at MSR-Electronic</li>
<li>Device can be used independently of control center, stand-alone devices without DGC-06</li>
<li>Individual parameterization possible</li>
<li>Robust against dust, humidity and high/low temperatures, protection class IP66</li>
<li>Ideal for heating or cooling applications</li>
</ul>
]]></content:encoded>
					
		
		
			</item>