<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Hanon &#8211; Phoenix Scientific Co., Ltd.</title>
	<atom:link href="https://phoenix-sci.com/brands/hanon/feed/" rel="self" type="application/rss+xml" />
	<link>https://phoenix-sci.com</link>
	<description>A Thailand’s leading provider in scientific and lab solutions.</description>
	<lastBuildDate>Wed, 07 Oct 2026 08:22:44 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.3</generator>

<image>
	<url>https://phoenix-sci.com/wp-content/uploads/2024/09/cropped-2025_LOGO-Phoenix-01-Photoroom-32x32.png</url>
	<title>Hanon &#8211; Phoenix Scientific Co., Ltd.</title>
	<link>https://phoenix-sci.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>SH230N Heavy Metal Digestor</title>
		<link>https://phoenix-sci.com/product/sh230n-heavy-metal-digestor/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 07 Oct 2026 08:06:33 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28188</guid>

					<description><![CDATA[SH230N Heavy Metal Digestor, with the advantages of rapid disintegration, high efficiency, convenience and large processing capacity, is suitable for food, medicine, agriculture, forestry, environmental protection, chemical, biochemical and other industries, as well as higher education institutions, scientific research departments on soil, feed, food, ore, etc.

It is suitable for use with atomic absorption, atomic fluorescence, ICP-AES and other analytical instruments.]]></description>
										<content:encoded><![CDATA[<p><strong>Functional Features</strong></p>
<ul>
<li>The temperature inside the furnace is continuously adjustable, the temperature of the controlled point is constant, the heat transfer efficiency is high, and the instrument is easy to operate.</li>
<li>The Teflon coating can effectively prevent the corrosion of the instrument by the acid and acid gas generated during the digestion process.</li>
<li>Deflector tank design prevents acid from splashing into the circuit during the experiment</li>
<li>Over-voltage, over-current, overheating and other multiple protections for the whole machine</li>
<li>Embedded software temperature control technology, precise, stable and uniform temperature control, small average temperature difference in the furnace, good consistency of sample digestion</li>
<li>Intelligent monitoring of the working status of each heating unit, real-time control of instrument operation</li>
<li>Eco-friendly fiber and air duct insulation for better insulation</li>
<li>Teflon and borosilicate glass test tubes are available</li>
<li>Surrounding three-dimensional heating, so that all parts of the sample are evenly heated, to prevent the maximum extent of heat dissipation</li>
<li>Real-time human-machine dialogue, experiment time to cut off the output</li>
</ul>
<p>&nbsp;</p>
<table border="0" cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center" width="332">
<p align="justify"><strong>Technical parameters</strong></p>
</td>
<td valign="center" width="284">
<p align="justify">
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Product Model</p>
</td>
<td valign="center" width="284">
<p align="justify">SH230N</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Temperature control range</p>
</td>
<td valign="center" width="284">
<p align="justify">Room temperature +5℃～ 450℃</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Temperature control accuracy</p>
</td>
<td valign="center" width="284">
<p align="justify">±0.1°C</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Heating method</p>
</td>
<td valign="center" width="284">
<p align="justify">Infrared heating and high purity graphite conduction</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Thermal insulation</p>
</td>
<td valign="center" width="284">
<p align="justify">Eco-friendly fiber and air duct insulation</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Anti-corrosion on the upper surface of the housing</p>
</td>
<td valign="center" width="284">
<p align="justify">Part stainless steel Part Teflon</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Digestion tube</p>
</td>
<td valign="center" width="284">
<p align="justify">Glass tube with scale 50mL (full capacity 100mL)</p>
<p align="justify">PTFE tube without scale (full capacity 70mL)</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Processing Capacity</p>
</td>
<td valign="center" width="284">
<p align="justify">30pcs/lot</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Power supply</p>
</td>
<td valign="center" width="284">
<p align="justify">220V AC±10% 50Hz</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Power Rating</p>
</td>
<td valign="center" width="284">
<p align="justify">3.6KW</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Dimension (L×W×H)</p>
</td>
<td valign="center" width="284">
<p align="justify">515mm421mmX211mm</p>
</td>
</tr>
<tr>
<td valign="center" width="332">
<p align="justify">Net weight</p>
</td>
<td valign="center" width="284">
<p align="justify">22Kg</p>
</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DF06 Automatic Dietary Fiber Analyzer</title>
		<link>https://phoenix-sci.com/product/df06-automatic-dietary-fiber-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 28 Sep 2026 08:28:33 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28085</guid>

					<description><![CDATA[Hanon DF06 Automatic Dietary Fiber Analyzer is designed for the determination of total dietary fiber (TDF), insoluble dietary fiber (IDF) and soluble dietary fiber (SDF) in food samples. The system automates liquid addition, heating, stirring, precipitation and vacuum filtration, reducing repetitive manual operations and improving dietary fiber testing efficiency.]]></description>
										<content:encoded><![CDATA[<p><strong>Key features:</strong></p>
<p><strong>Efficient &amp; Automatic</strong></p>
<ul>
<li>Integrates automatic liquid addition, heating, stirring, precipitation and vacuum filtration.</li>
<li>Automatically controls the opening and closing of the reaction bag during enzymatic digestion, helping prevent reagent evaporation at high temperature.</li>
<li>Uses a straight-through flexible reaction bag so the sample is automatically transferred to the filtration section after precipitation without manual sample transfer.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Accurate &amp; Reliable</strong></p>
<ul>
<li>Built-in automatic pipeline cleaning helps prevent blockage caused by deteriorated enzyme solution and improves liquid-addition accuracy.</li>
<li>Real-time temperature control and monitoring for each channel, with temperature control accuracy within ±1°C.</li>
<li>Non-contact stirring promotes efficient mixing of the sample and enzyme solution while avoiding direct contact between the stirrer and sample.</li>
<li>Uses filter membranes instead of traditional crucibles. The membrane can be directly digested and ashed with the sample, reducing errors caused by sample-transfer residue.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Easy to Use</strong></p>
<ul>
<li>Ergonomic lifting-arm operating platform allows the control screen position to be adjusted.</li>
<li>Built-in method library allows preset methods to be recalled with one touch for automatic testing.</li>
<li>Six channels can be independently controlled and selected according to the number of samples.</li>
<li>Vacuum filtration requires no back-blowing or external gas source.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Safety &amp; Compliance</strong></p>
<ul>
<li>Complies with relevant FDA 21 CFR Part 11 requirements, with three-level username and password login and traceable instrument operations.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Related Standards:</strong></p>
<ul>
<li style="list-style-type: none;">
<ul>
<li>GB 5009.88 — National Food Safety Standard: Determination of Dietary Fiber in Foods</li>
<li>GB/T 22224-2008 — Determination of Dietary Fiber in Foods by Enzymatic-Gravimetric Method and Enzymatic-Gravimetric–Liquid Chromatography Method</li>
<li>AOAC 985.29 — Total Dietary Fiber in Foods</li>
<li>AOAC 991.43 — Total, Soluble, and Insoluble Dietary Fiber in Foods</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table>
<tbody>
<tr>
<td width="336"><strong>Specification</strong></td>
<td width="336"><strong>DF06</strong></td>
</tr>
<tr>
<td width="336">Sample weight</td>
<td width="336">0.2–1 g</td>
</tr>
<tr>
<td width="336">Measuring range</td>
<td width="336">0–100%</td>
</tr>
<tr>
<td width="336">Standard deviation</td>
<td width="336">≤1%</td>
</tr>
<tr>
<td width="336">Temperature control accuracy</td>
<td width="336">±1°C</td>
</tr>
<tr>
<td width="336">Batch capacity</td>
<td width="336">6 samples</td>
</tr>
<tr>
<td width="336">Test time</td>
<td width="336">TDF: 3.5 h; single IDF or SDF: 1–3 h, depending on sample type</td>
</tr>
<tr>
<td width="336">Filtration method</td>
<td width="336">Vacuum filtration; no back-blowing required</td>
</tr>
<tr>
<td width="336">Power supply</td>
<td width="336">AC 220 ±10 V, (50 ±1) Hz</td>
</tr>
<tr>
<td width="336">Rated power</td>
<td width="336">1300 W</td>
</tr>
<tr>
<td width="336">Dimensions (L × W × H)</td>
<td width="336">800 × 350 × 650 mm</td>
</tr>
<tr>
<td width="336">Net weight</td>
<td width="336">60 kg</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>F2000 Fully Automatic Fiber Analyzer</title>
		<link>https://phoenix-sci.com/product/f2000-fully-automatic-fiber-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Mon, 28 Sep 2026 08:09:02 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/?post_type=product&#038;p=28083</guid>

					<description><![CDATA[Hanon F2000 Fully Automatic Fiber Analyzer is an automatic fiber analyzer for the determination of crude fiber, NDF, ADF, cellulose, hemicellulose and acid detergent lignin (ADL) in food, feed and plant samples. The system integrates digestion, filtration, washing and waste discharge, using filter bags instead of crucibles. With one-button operation, the F2000 can process more than 24 samples per batch for efficient fiber analysis.]]></description>
										<content:encoded><![CDATA[<p><strong>Key features:</strong></p>
<ul>
<li>7-inch touch screen with built-in Android operating system. Fully automatic operation completes liquid addition, digestion, stirring, washing and waste discharge with one touch, requiring no manual intervention throughout the process.</li>
<li>Method-library management with built-in CF, NDF and ADF programs. More than 1,000 test programs can be configured, and users can edit programs according to sample type and test item.</li>
<li>Filter-bag technology effectively reduces sample caking and crucible blockage during testing, improving experimental efficiency.</li>
<li>More than 24 samples can be loaded per batch, improving sample throughput.</li>
<li>Built-in preheating function preheats water during the test in accordance with fiber determination methods requiring hot-water washing, supporting measurement accuracy.</li>
<li>Integrated metal digestion vessel with specially treated surface provides resistance to high temperature, high pressure and chemical corrosion.</li>
<li>User permission management allows accounts and operating permissions to be configured for safer laboratory operation.</li>
<li>Low-liquid alarm automatically warns and stops the instrument when solvent is insufficient.</li>
<li>Dual temperature and pressure monitoring. Heating stops automatically under over-temperature conditions; if pressure exceeds the mechanical safety-valve limit, the valve opens automatically to release pressure.</li>
<li>Safety door with electromagnetic lock automatically locks the digestion-vessel cover during operation to prevent accidental operation.</li>
<li>The instrument operates as a closed system and can complete the test without cooling water.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table>
<tbody>
<tr>
<td width="336"><strong>Specification</strong></td>
<td width="336"><strong>F2000</strong></td>
</tr>
<tr>
<td width="336"><strong>Sample weight</strong></td>
<td width="336">0.5–1 g</td>
</tr>
<tr>
<td width="336"><strong>Measuring range</strong></td>
<td width="336">0–100%</td>
</tr>
<tr>
<td width="336"><strong>Temperature control accuracy</strong></td>
<td width="336">±0.1°C</td>
</tr>
<tr>
<td width="336"><strong>Repeatability</strong></td>
<td width="336">≤0.5%</td>
</tr>
<tr>
<td width="336"><strong>Maximum samples per batch</strong></td>
<td width="336">24 positions</td>
</tr>
<tr>
<td width="336"><strong>Daily throughput</strong></td>
<td width="336">≥4 batches (≥96 samples)</td>
</tr>
<tr>
<td width="336"><strong>Power supply</strong></td>
<td width="336">AC 220 ±10% V, (50 ±1) Hz</td>
</tr>
<tr>
<td width="336"><strong>Rated power</strong></td>
<td width="336">2000 W</td>
</tr>
<tr>
<td width="336"><strong>Dimensions (L × W × H)</strong></td>
<td width="336">520 × 450 × 510 mm</td>
</tr>
<tr>
<td width="336"><strong>Net weight</strong></td>
<td width="336">52 kg</td>
</tr>
</tbody>
</table>
<p>&nbsp;</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SH220F Kjeldahl Digestion System</title>
		<link>https://phoenix-sci.com/product/sh220f-kjeldahl-digestion-system/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/kjeldahl-digestion-system/</guid>

					<description><![CDATA[The SH220F has two temperature control modes: curve heating and linear temperature heating. It can edit and store 10 groups of digestion programs. Each group can set up a segment temperature and time gradient of up to 5 to meet different experimental needs of users.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>20 positions, enhance working efficiency rapidly.</li>
<li>Corrosion-resistant design.</li>
<li>It adopt advanced insulation technology, eco-friendly, reduce energy intensity maximum limitedly.</li>
<li>Multi-protection, Over-current protection, high temperature warning, overload protection.</li>
<li>LCD display.</li>
<li>It’s used with microwave reaction system, pretreat for microwave digestion or removing acid after digestion.</li>
<li>Linear and curve temperature rise mode, up to 5 stages temperature setting.</li>
<li>Curve temperature rise and linear temperature rise two temperature control modes.</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center" width="186">
<p align="center">
</td>
<td valign="center" width="235">
<p align="center">SH420F</p>
</td>
<td valign="center" width="167">
<p align="center">SH220F</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature range</td>
<td valign="center" width="225">Room temperature +5 &#8211; 450℃</td>
<td>
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature accuracy</td>
<td valign="center" width="225">±1℃</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating method</td>
<td valign="center" width="225">Infrared heating and high-purity graphite conduction</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating insulation method</td>
<td valign="center" width="225">Unique air duct insulation technology</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Digestion tube capacity</td>
<td valign="center" width="225">300mL</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Capacity per batch</td>
<td valign="center" width="225">20pcs/batch</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power supply</td>
<td valign="center" width="225">220 VAC±10% 50HZ</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power</td>
<td valign="center" width="225">3600W</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Dimensions</td>
<td valign="center" width="235">515mmX458mmX730mm</td>
<td valign="center" width="167">515mmX421mmX211mm</td>
</tr>
<tr>
<td valign="center" width="186">Net weight</td>
<td valign="center" width="235">40Kg</td>
<td valign="center" width="167">25Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>SH420F Kjeldahl Digestion System</title>
		<link>https://phoenix-sci.com/product/sh420f-kjeldahl-digestion-system-2/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/kjeldahl-digestion-system-2/</guid>

					<description><![CDATA[Hanon SH420F Kjeldahl Digestor adopts advanced high-temperature infrared radiation heating technology and microprocessor control platform, boasts accurate temperature control and quick temperature rise.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Can digest 20 samples at the same time</li>
<li>Using infrared radiation graphite conduction heating method, the heating speed is fast, and the temperature difference between the holes is small</li>
<li>Adopt PID temperature control technology, high temperature control accuracy, fast heating speed, only 25 minutes from room temperature to 400℃</li>
<li>2 heating methods: curve heating and linear heating, 500 groups of digestion programs can be edited and stored, and each group can be set up to 25 segments</li>
<li>Temperature and time gradient to meet different experimental needs of users</li>
<li>The surface of the instrument is coated with Teflon, and the whole machine is treated with anti-corrosion treatment to avoid the corrosion of the machine by acidic liquids during the experiment</li>
<li>Using 5.6 inch large screen true color LCD display system, intuitive and convenient operation</li>
<li>The whole machine has multiple protections such as over-voltage, over-current, over-heating, etc., and over-temperature alarm function</li>
<li>Adopt advanced ceramic and air duct heat insulation technology to make the experiment operation safer</li>
<li>Standard simple cooling rack, digestion tube can be cooled quickly, improve work efficiency</li>
<li>Optional waste gas neutralization system, through condensation, neutralization and drying to eliminate the acid gas generated during the experiment</li>
</ul>
<p>&nbsp;</p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center" width="186">
<p align="center">
</td>
<td valign="center" width="235">
<p align="center">SH420F</p>
</td>
<td valign="center" width="167">
<p align="center">SH220F</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature range</td>
<td valign="center" width="225">Room temperature +5 &#8211; 450℃</td>
<td>
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Temperature accuracy</td>
<td valign="center" width="225">±1℃</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating method</td>
<td valign="center" width="225">Infrared heating and high-purity graphite conduction</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Heating insulation method</td>
<td valign="center" width="225">Unique air duct insulation technology</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Digestion tube capacity</td>
<td valign="center" width="225">300mL</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Capacity per batch</td>
<td valign="center" width="225">20pcs/batch</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power supply</td>
<td valign="center" width="225">220 VAC±10% 50HZ</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Power</td>
<td valign="center" width="225">3600W</td>
<td valign="center" width="177">
<p align="center">≈</p>
</td>
</tr>
<tr>
<td valign="center" width="186">Dimensions</td>
<td valign="center" width="235">515mmX458mmX730mm</td>
<td valign="center" width="167">515mmX421mmX211mm</td>
</tr>
<tr>
<td valign="center" width="186">Net weight</td>
<td valign="center" width="235">40Kg</td>
<td valign="center" width="167">25Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Digestor (SH520/SH508)</title>
		<link>https://phoenix-sci.com/product/automatic-digestor/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-digestor/</guid>

					<description><![CDATA[Fully automatic digestor adhering to the design concept of "reliable, intelligent and environmentally friendly", which can automatically complete the digestion process base on Kjeldahl method experiments.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristic:</strong></p>
<ul>
<li>Fully automatic operation, using Android system for controlling the lifting device and exhaust gas neutralization.</li>
<li>Options for 8 or 20 sample positions.</li>
<li>Aluminum deep-hole heating module for improved heating efficiency.</li>
<li>Real-time temperature monitoring and data storage.</li>
<li>Pre-installed and customizable digestion methods.</li>
<li>Energy-efficient design with ceramic and air duct heat insulation.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" />
<col width="189" /></colgroup>
<tbody>
<tr>
<td style="text-align: center;"><strong>Model</strong></td>
<td style="text-align: center;"><strong>SH520</strong></td>
<td style="text-align: center;"><strong>SH508</strong></td>
</tr>
<tr>
<td>Temperature Range</td>
<td>Room temperature +5°C~450C</td>
<td>Room temperature +5C~450C</td>
</tr>
<tr>
<td>Temperature accuracy</td>
<td>±1°℃</td>
<td>±1°℃</td>
</tr>
<tr>
<td>Heating Method</td>
<td>Electric heating tube</td>
<td>Electric heating tube</td>
</tr>
<tr>
<td>Digestion Tube</td>
<td>300mL</td>
<td>300mL / 380mL</td>
</tr>
<tr>
<td>Digestion Capacity</td>
<td>20 Positions</td>
<td>8 Positions</td>
</tr>
<tr>
<td>Lifting</td>
<td>Yes</td>
<td>Yes</td>
</tr>
<tr>
<td>Mainfold</td>
<td>Yes</td>
<td>Yes</td>
</tr>
<tr>
<td>Scrubber</td>
<td>Optional</td>
<td>Optional</td>
</tr>
<tr>
<td>Interface</td>
<td>WIFI / USB</td>
<td>WIFI / USB</td>
</tr>
<tr>
<td>Power Supply</td>
<td>AC 220±10%V(50±1)Hz</td>
<td>AC 220±10%V(50±1)Hz</td>
</tr>
<tr>
<td>Rated Power</td>
<td>2300W</td>
<td>1400W</td>
</tr>
<tr>
<td>Dimension (LxWxH)</td>
<td>305mm*590mm*151mm</td>
<td>328mm*440mm*151mm</td>
</tr>
<tr>
<td>Net Weight</td>
<td>21Kg</td>
<td>15Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Semi-auto Fat Analyzer</title>
		<link>https://phoenix-sci.com/product/semi-auto-fat-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/semi-auto-fat-analyzer/</guid>

					<description><![CDATA[Hanon SOX406 Fat Analyzer is based on the Soxhlet extraction principle and integrates such functions as soaking, extraction, leaching, heating, condensation and solvent recovery.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Integral metal heating, wide scope and high precision of temperature control.</li>
<li>Electric circuit is isolated from the extraction space, ensuring device security.</li>
<li>Timer and timing functions are available.</li>
<li>Over-temperature alarming and timer reminding functions are available.</li>
<li>Exclusive air insulation technique leaves the case in room temperature, has thermal insulation and temperature maintenance two functions.</li>
<li>4.3&#8243; LCD screen and microcomputer control system are adopted.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" /></colgroup>
<tbody>
<tr>
<td>Temperature range</td>
<td>Room temperature+5℃ ~ 280℃</td>
</tr>
<tr>
<td>Measuring range</td>
<td>0~100%</td>
</tr>
<tr>
<td>Temperature accuracy</td>
<td>±1℃</td>
</tr>
<tr>
<td>Sample weight</td>
<td>
<div>
<div>0.5~15g(generally 2 ~ 5g,depending on sample)</div>
</div>
</td>
</tr>
<tr>
<td>Capacity per batch</td>
<td>6pcs/batch</td>
</tr>
<tr>
<td>Solvent cup volume</td>
<td>80mL</td>
</tr>
<tr>
<td>Solvent recovery</td>
<td>≥80%</td>
</tr>
<tr>
<td>Shortened extraction time</td>
<td>20~80%</td>
</tr>
<tr>
<td>Power supply</td>
<td>220VAC±10%, 50Hz</td>
</tr>
<tr>
<td>Power</td>
<td>1KW</td>
</tr>
<tr>
<td>Dimensions</td>
<td>650mm×320mm×715mm</td>
</tr>
<tr>
<td>Net Weight</td>
<td>35Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Fat Analyzer</title>
		<link>https://phoenix-sci.com/product/automatic-fat-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-fat-analyzer/</guid>

					<description><![CDATA[SOX606 Automatic Soxhlet Extractor, designed based on the Soxhlet extraction principle with weight method to determine the fat content.]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Automatic extraction: One touch to start extraction, lifting, pre-heating, extraction, dilution, solvent recovery automatically.</li>
<li>In-built 5 unique methods of extraction, handy operation: Include Soxhlet Extraction, Soxhlet Hot Extraction, Continue Flow Extraction, Hot Extraction, CH Standard methods.</li>
<li>Apply to all organic solvents: Customized by glass and PTFE, which can block all impurities and possess high rate of accuracy, apply to all organic solvents, satisfying the requirements of users.</li>
<li>ECO- friendly and conservation: Full temperature and flow control for reduce consumption of condensed water.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" /></colgroup>
<tbody>
<tr>
<td>Temperature range</td>
<td>Room temperature +5℃~ 300℃</td>
</tr>
<tr>
<td>Measuring range</td>
<td>0.1~100%</td>
</tr>
<tr>
<td>Temperature accuracy</td>
<td>±1℃</td>
</tr>
<tr>
<td>Reproducibility</td>
<td>Relative error 1%</td>
</tr>
<tr>
<td>Sample weight</td>
<td>0.5~15g</td>
</tr>
<tr>
<td>Capacity per batch</td>
<td>6pcs/batch</td>
</tr>
<tr>
<td>Solvent cup volume</td>
<td>150mL</td>
</tr>
<tr>
<td>Solvent recovery</td>
<td>≥85%</td>
</tr>
<tr>
<td>Controller</td>
<td>External via cable</td>
</tr>
<tr>
<td>Power supply</td>
<td>220VAC±10%, 50Hz</td>
</tr>
<tr>
<td>Display</td>
<td>7 inches color touch screen</td>
</tr>
<tr>
<td>Power</td>
<td>2.6KW</td>
</tr>
<tr>
<td>Dimensions</td>
<td>650mmx380mmx720mm</td>
</tr>
<tr>
<td>Net Weight</td>
<td>50Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>K1100F Automatic Kjeldahl Analyzer</title>
		<link>https://phoenix-sci.com/product/k1100f-automatic-kjeldahl-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-kjeldahl-analyzer/</guid>

					<description><![CDATA[Hanon K1100F Automatic Kjeldahl Analyzer is an automatic device integrating distillation and titration functions and it is designed based on classic Kjeldahl nitrogen determination method. It's equipped with the latest core control system, powerful automation and high-quality components]]></description>
										<content:encoded><![CDATA[<p><strong>Characteristics:</strong></p>
<ul>
<li>Automatic distillation, titration, calculation, printing, drain and cleaning function, safety and time-saving.</li>
<li>Visible titration cup design gives the operator real-time control of the whole test process.</li>
<li>Steam flow is controllable, satisfying different test requirements.</li>
<li>Regent tank enjoys fluid absence warning function, ensuring smooth test going.</li>
<li>High-precision charging pump and titration system ensure test results accuracy.</li>
<li>Large LCD touch screen gives visual operation, and enabling user to have a good command of it.</li>
<li>USB or RS485 interface is optional for PC connection.</li>
<li>Distilled liquid temperature is detected real-time. Emergency stop against temp anomaly.</li>
<li>Double distillation model meets different experiments, to retard the speed of acid-base reaction.</li>
<li>Digestion tube fast drain function is used to avoid operator touch distilled hot reagents, protecting operators.</li>
<li>The printer is built in.</li>
</ul>
<p>&nbsp;</p>
<p><strong>Specifications:</strong></p>
<table cellspacing="0" cellpadding="5">
<tbody>
<tr>
<td valign="center">Measuring range</td>
<td valign="center">0.1mg ～240mg N</td>
</tr>
<tr>
<td valign="center">Analysis time</td>
<td valign="center">5～10min/sample</td>
</tr>
<tr>
<td valign="center">Reproducibility</td>
<td valign="center">Average value relative error ±0.5%</td>
</tr>
<tr>
<td valign="center">Recovery</td>
<td valign="center">≧99.5%</td>
</tr>
<tr>
<td valign="center">Burette volume</td>
<td valign="center">1.0μL/step</td>
</tr>
<tr>
<td valign="center">Sample capacity</td>
<td valign="center">solid≦5g/sample, liquid≦20mL/sample</td>
</tr>
<tr>
<td valign="center">Water consumption in the distillation process</td>
<td valign="center">1.5L/min</td>
</tr>
<tr>
<td valign="center">Data storage capacity</td>
<td valign="center">1800 groups</td>
</tr>
<tr>
<td valign="center">Power supply</td>
<td valign="center">220VAC±10%, 50Hz</td>
</tr>
<tr>
<td valign="center">Power</td>
<td valign="center">2Kw</td>
</tr>
<tr>
<td valign="center">Net weight</td>
<td valign="center">38Kg</td>
</tr>
<tr>
<td valign="center">Dimensions</td>
<td valign="center">455mm×391mm×730mm</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Automatic Kjeldahl Protein/Nitrogen Analyzer</title>
		<link>https://phoenix-sci.com/product/automatic-kjeldahl-protein-nitrogen-analyzer/</link>
		
		<dc:creator><![CDATA[Nick Phoenix]]></dc:creator>
		<pubDate>Wed, 26 Feb 2025 06:07:31 +0000</pubDate>
				<guid isPermaLink="false">https://phoenix-sci.com/product/automatic-kjeldahl-protein-nitrogen-analyzer/</guid>

					<description><![CDATA[Hanon K1160 Automatic Kjeldahl Protein/Nitrogen Analyzer is unique in its intelligence, efficiency, energy saving and data sharing, bringing more new experiences to users. The product can be widely used in the fields of food processing, feed production, tobacco, animal husbandry, soil fertility, environmental monitoring, medicine, agriculture, scientific research, teaching, quality supervision and other fields of nitrogen or protein determination.]]></description>
										<content:encoded><![CDATA[<p><strong>Features:</strong></p>
<ul>
<li>Automation, fully automatic distillation, titration, fault self-test, calculation, printing, waste disposal.</li>
<li>Can be paired with K1124 24-position autosampler.</li>
<li>Compliance with FDA 21CFR Part 11 and GMP.</li>
<li>High accuracy, burette accuracy can be adjust from 0.2 to 1μL/Step.</li>
</ul>
<p>&nbsp;</p>
<table dir="ltr" cellspacing="0" cellpadding="0" data-sheets-root="1" data-sheets-baot="1">
<colgroup>
<col width="229" />
<col width="254" /></colgroup>
<tbody>
<tr>
<td style="text-align: left;" colspan="2" rowspan="1"><strong>K1160 Kjeldahl Protein Analyzer</strong></td>
</tr>
<tr>
<td>Measuring range</td>
<td>0.1mg ～240mg N</td>
</tr>
<tr>
<td>Analysis time</td>
<td>3～8min/sample</td>
</tr>
<tr>
<td>Reproducibility</td>
<td>Average value relative error ±0.5%</td>
</tr>
<tr>
<td>Recovery</td>
<td>≧99.5%</td>
</tr>
<tr>
<td>Burette volume</td>
<td>
<div>
<div>1.0μL/step optional: 0.2μL/step and 0.4μL/step</div>
</div>
</td>
</tr>
<tr>
<td>Sample capacity</td>
<td>solid≦5g/sample, liquid≦20mL/sample</td>
</tr>
<tr>
<td>Water consumption in the distillation process</td>
<td>0.5L/min</td>
</tr>
<tr>
<td>Data storage capacity</td>
<td>1 million groups</td>
</tr>
<tr>
<td>Power supply</td>
<td>220VAC±10%, 50Hz</td>
</tr>
<tr>
<td>Power</td>
<td>2Kw</td>
</tr>
<tr>
<td>Net weight</td>
<td>38Kg</td>
</tr>
<tr>
<td>Dimensions</td>
<td>460mm×360mm×725mm</td>
</tr>
<tr>
<td style="text-align: left;" colspan="2" rowspan="1"><strong>K1124 Auto Sampler</strong></td>
</tr>
<tr>
<td>Capacity</td>
<td>24 samples per batch</td>
</tr>
<tr>
<td>Rotor speed</td>
<td>≥0.04r/s</td>
</tr>
<tr>
<td>Sampling speed</td>
<td>≥40mm/s</td>
</tr>
<tr>
<td>Tank capacity</td>
<td>4×15L</td>
</tr>
<tr>
<td>Connection</td>
<td>CAN</td>
</tr>
<tr>
<td>Voltage</td>
<td>24V DC</td>
</tr>
<tr>
<td>Rated Power</td>
<td>40W</td>
</tr>
<tr>
<td>Dimension(L×W×H)</td>
<td>920mm×625mm×908mm</td>
</tr>
<tr>
<td>Weight</td>
<td>80Kg</td>
</tr>
</tbody>
</table>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
